100-199, Primary Processor Test Error Codes
The 100 series of diagnostic error codes identifies failures with processor and system board
functions generated by Compaq Server Diagnostics.
Table 3-3
Primary Processor Test Error Codes
Error Code
Description
Recommended Action
101-xx
CPU test failed
Replace the processor board and retest.
103-xx
DMA page registers test failed
104-xx
Interrupt controller master test
failed
105-xx
Port 61 error
106-xx
Keyboard controller self-test failed
Replace the processor board and retest.
107-xx
CMOS RAM test failed
108-xx
CMOS interrupt test failed
109-xx
CMOS clock load data test failed
1.
Replace the battery/clock module and retest.
2.
Replace the system board and retest.
110-xx
Programmable timer load data test
failed
111-xx
Refresh detect test failed
113-xx
Protected mode test failed
Replace the processor board and retest.
114-xx
Speaker test failed
1.
Verify the speaker connection and retest.
2.
Replace the speaker and retest.
3.
Replace the system board and retest.
116-xx
Cache test failed
Replace the system board and retest.
122-xx
Multiprocessor Dispatch test failed
123-xx
Interprocessor Communication
test failed
1.
Check the system configuration and retest.
2.
Replace the processor board and retest.
3.
Replace the system board and retest.
199-xx
Installed devices test failed
1.
Check the system configuration and retest.
2.
Verify cable connections and retest.
3.
Check switch and/or jumper settings and retest.
4.
Run the Configuration Utility and retest.
5.
Replace the processor board and retest.
6.
Replace the system board and retest.