Compaq PROLIANT ML370 User Manual
Page 73
![background image](/manuals/61044/73/background.png)
Diagnostics and Troubleshooting 3-19
Table 3-2
POST Error Messages
continued
Error Code
Audible Beeps
Probable Source of Problem
Recommended Action
1778 - Slot x Drive
Array resuming
Automatic Data
Recovery process
None
This message appears whenever
a controller reset or power cycle
occurs while Automatic Data
Recovery is in progress.
No action required. This
message appears whenever a
controller reset or power cycle
occurs while Automatic Data
Recovery is in progress.
1779 - Slot x Drive
Array—replacement
drives detected OR
previously failed
drive(s) now appear
to be operational:
Port (y): SCSI ID (x):
Restore data from
backup if
replacement drive x
has been installed.
None
Intermittent drive failure and/or
possible loss of data
If this message appears and
drive x (identified by its SCSI ID)
has not been replaced, this
indicates an intermittent drive
failure. This message also
appears once immediately
following drive replacement
whenever data must be restored
from backup.
1780 - Disk 0 Failure
None
Hard drive/format error
Run Diagnostics. Replace failed
assembly as indicated.
1781 - Disk 1 Failure
None
Hard drive/format error
Run Diagnostics. Replace failed
assembly as indicated.
1782 - Disk
Controller Failure
None
Hard disk drive circuitry error
Run Diagnostics. Replace failed
assembly as indicated.
1783 - Slot x Drive
Array Controller
Failure
None
ROM installation problem or
Array Accelerator board problem
If this message appears
immediately following a ROM
installation, the ROM is
defective or not installed
properly. Check that the
controller is firmly inserted in its
slot. Try upgrading the System
ROMs. Otherwise, replace the
Integrated Smart Array
Controller.
1784 - Slot x Drive
Array Drive Failure.
The following SCSI
drive(s) should be
replaced: SCSI
port (y) SCSI ID (x).
None
Defective drive and/or cables
Check for loose cables. Replace
defective drive x and/or
cable(s).
continued