Compaq PROLIANT ML370 User Manual
Page 67
Diagnostics and Troubleshooting 3-13
Table 3-2
POST Error Messages
continued
Error Code
Audible Beeps
Probable Source of Problem
Recommended Action
1702 - SCSI cable
error detected;
system halted.
None
Termination or cabling problem
with the system board integrated
SCSI controller.
Refer to cabling diagrams in
Chapter 2 of this guide, the
cabling guidelines on the
Compaq website, and your
Compaq server documentation.
1703 - SCSI cable
error detected.
Internal SCSI cable
not attached to
system board
connector. System
halted.
None
Incorrect cabling
Ensure that the integrated SCSI
controller has SCSI termination
attached.
1720 - Slot x Drive
Array—SMART hard
Drive Detects
Imminent Failure
SCSI: Port n:
SCSI ID x
None
Prefailure condition
Indicated drive has reported a
SMART predictive-failure
condition and may fail at some
time in the future. If drive is part
of a non-fault-tolerant
configuration, back up all data
before replacing drive and
restore all data afterward. If
drive is part of a fault-tolerant
configuration do not replace the
drive unless all other drives in
the array are online. Press F1 to
resume.
1721 - Slot x Drive
Array—Drive
parameter tracking
predicts imminent
failure. The following
devices should be
replaced when
conditions permit. Do
not replace drive
unless all other
drives in the array
are online! Back up
data before replacing
drive(s) if using
RAID 0.
None
Monitor and performance
threshold exceeded condition.
Replace the drive when it is
reasonable for you to do. The
drive has not failed, but Compaq
recommends you replace the
drive.
continued