Compaq PROLIANT ML370 User Manual
Page 64

3-10 Compaq ProLiant ML370 Maintenance and Service Guide
Table 3-2
POST Error Messages
continued
Error Code
Audible Beeps
Probable Source of Problem
Recommended Action
215 - Processor
Power Module has
lost Redundancy in
Socket x
None
PPM (DC-DC Converter) has lost
redundancy.
Run Diagnostics. Replace failed
assembly as indicated.
215 - Nonfunctioning
Voltage Regulator
Module for
Processors
None
PPM (DC-DC Converter) has
failed or lost redundancy.
Run Diagnostics. Replace failed
assembly as indicated.
216 - Voltage
Regulator Module for
Processor X no
longer redundant
None
Redundancy failed in PPM
To restore redundancy, replace
the PPM.
216 - Processor PPM
has lost Redundancy,
Module X
None
Indicated PPM (DC-DC Converter)
has lost redundancy
Replace failed assembly as
indicated.
218 - Cache
Accelerators Not
Installed. System
Halted.
None
Cache accelerators not installed
or improperly installed
Check cache accelerator
installation.
219 - Tag Update
Rules SRAM Failure.
System Halted.
None
Catastrophic chipset failure
Call Compaq service provider.
219 - Snoop Rules
SRAM Failure.
System Halted.
None
Catastrophic chipset failure
Call Compaq service provider.
220 - Cache
Accelerator Slot x
Initialization Failed.
System Halted.
None
Cache accelerator in slot x
improperly installed or bad
Check cache accelerator
installation and if properly
installed, replace.
221 - Power Fault On
Processor Bus X
None
A PPM on indicated bus is in a
failed state.
Run Diagnostics. Replace failed
assembly as indicated.
301 - Keyboard Error
None
Keyboard failure
Turn off the computer, then
reconnect the keyboard.
301 - Keyboard Error
or Test Fixture
Installed
None
Keyboard failure
Replace the keyboard.
continued