3-12 Compaq ProLiant ML370 Maintenance and Service Guide

Table 3-2
POST Error Messages

continued

Error Code

Audible Beeps

Probable Source of Problem

Recommended Action

1611 - I/O Fan
(Fan X) failure
detected

2S

I/O fan has failed

Replace the failed fan.

1611 - CPU Fan
(Fan X) failure
detected

2S

CPU fan has failed

Replace the failed fan.

1612 - Primary
power supply failure

2S

Primary power supply has failed

Replace power supply as soon
as possible.

1613 - Low System
Battery

None

Real time clock system battery is
running low on power

Run Diagnostics. Replace failed
assembly as indicated.

1615 - Power Supply
Failure, Power
Supply Unplugged, or
Power Supply Fan
Failure in Bay X

None

A power supply has failed.

Replace or check specified
power supply.

1617 - Fan controller
not responding

2S

Fan controller failure

Check and replace failed
controller assembly.

1617 - I/O Fan
controller not
responding

2S

I/O fan controller failure

Check and replace failed
controller assembly.

1617 - CPU Fan
controller not
responding

2S

CPU fan controller failure

Check and replace failed
controller assembly.

1620 - Locked SCSI
Bus Detected. Verify
SCSI bus cabling.
System halted.

None

SCSI bus failure

Run Diagnostics. Replace failed
assembly as indicated.

1621 - Current SCSI
bus cable
configuration is not
recommended

None

Improper SCSI bus cabling

Check documentation for proper
SCSI bus cabling.

1622 - Internal SCSI
Jumper Board Not
Installed

None

The system has detected that the
array enabler board is not
installed.

Install the array enabler board.

continued