Diagnostics and Troubleshooting 3-9
Table 3-2
POST Error Messages
continued
Error Code
Audible Beeps
Probable Source of Problem
Recommended Action
175 - Configuration/
Slot Mismatch Device
Found
None
PCI board added, configuration
not updated
Run the System Configuration
Utility and correct.
177 - Configuration
Not Complete
None
Incomplete system configuration
Run the System Configuration
Utility and correct.
178 - Processor
Configuration Invalid
None
Processor type or step does not
match configuration memory
Run the System Configuration
Utility and correct.
180 - Log
Reinitialized
None
N/A
N/A
201 - Memory Error
None
RAM failure
Run Diagnostics. Replace failed
assembly as indicated.
203 - Memory
Address Error
None
RAM failure
Run Diagnostics. Replace failed
assembly as indicated.
207 - Invalid Memory
Configuration—
Check DIMM [SIMM]
Installation
None
Memory module installed
incorrectly
Verify placement of memory
modules.
208 - Invalid Memory
Speed—Check
DIMM [SIMM]
Installation
1 long, 1 short
The speed of the memory is too
slow, where: xx00 = expansion
board SIMMs are too slow, or
00yy = system board SIMMs are
too slow. xx and yy have
corresponding bit set
The speed of the memory
modules must be 60 ns. Verify
the speed of the memory
modules installed and replace.
209 - Memory
Detection Failure.
Check Memory
Installation
1 long, 1 short
Unable to size memory
Check DIMM installation, and if
error persists, call Compaq
service provider.
211 - Cache Switch
Set Incorrectly
None
Switch not set properly during
installation or upgrade
Verify switch settings.
212 - System
Processor Failed/
Mapped out
1 short
Processor in slot x failed
Run Diagnostics and replace
failed processor.
214 - DC-DC
Converter Failed
None
PowerSafe Module (DC-DC
Converter) failed
Run Diagnostics. Replace failed
assembly as indicated.
214 - Processor PPM
Failed Module X
None
Indicated PPM (DC-DC Converter)
failed
Replace failed assembly as
indicated.
continued