Compaq PROLIANT ML370 User Manual
Page 62
3-8 Compaq ProLiant ML370 Maintenance and Service Guide
Table 3-2
POST Error Messages
Error Code
Audible Beeps
Probable Source of Problem
Recommended Action
A Critical Error
occurred prior to this
power-up
None
A catastrophic system error,
which caused the server to
crash, has been logged.
Run Diagnostics. Replace failed
assembly as indicated.
Unsupported
Processor Detected
System Halted
1 long, 1 short
Processor not supported by
current system ROM
Check documentation for
supported processors, and if
supported, remove the
processor and update the
system to latest ROM.
FATAL ROM ERROR:
The System ROM is
not properly
programmed
1 long, 1 short
ROM programmed in factory
incorrectly
Replace the physical ROM part.
101 - ROM Error
1 long, 1 short
System ROM checksum
Run Diagnostics. Replace failed
assembly as indicated.
101 - I/O ROM Error
None
Options ROM checksum
Run Diagnostics. Replace failed
assembly as indicated.
102 - System Board
Failure
None
DMA, timers, and so on
Replace the system board. Run
the Compaq System
Configuration Utility.
104 - ASR-2 Timer
Failure
None
System board failure
Run Diagnostics. Replace failed
assembly as indicated.
105 - Current System
ROM is corrupt—
now booting
redundant System
ROM
2L
Non-booted ROM image is
corrupt
Flash the ROM utilizing
ROMPaq.
162 - System
Options Not Set
2S
Configuration incorrect
Run the System Configuration
Utility and correct.
163—Time & Date
Not Set
2S
Invalid time or date in
configuration memory
Run the System Configuration
Utility and correct.
164 - Memory Size
Error
2S
Configuration memory incorrect
Run the System Configuration
Utility and correct.
172 - Configuration
Nonvolatile Memory
Invalid
None
Nonvolatile configuration corrupt
or jumper installed
Run the System Configuration
Utility and correct.
173 - Slot ID
Mismatch
None
Board replaced, configuration not
updated
Run the System Configuration
Utility and correct.
174 - Configuration/
Slot Mismatch Device
Not Found
None
PCI board not found
Run the System Configuration
Utility and correct.
continued