Cooper Instruments & Systems DFI Infinity CS Economy Digital Indicator User Manual
Page 8

DFI INFINITY CS (V- M3598/N/0906)
5
CF 70
MENU Button
In the Run Mode, press the MENU button to terminate the current measuring strain and enter you into the
Configuration Mode.
Only if you have not installed the lock out jumpers on the main board.
In the Configuration Mode, press the MENU button to store changes in the nonvolatile memory and then advance
you to the next menu item.
RESET Button
If you hard reset (press the MENU button followed by the RESET button) or power off/on the meter, it shows
,
followed by
.
In the Run Mode, press the RESET button to reset the latched setpoints. The meter shows
and returns to
the Run Mode.
In the Configuration Mode, press the RESET button once to review the previous menu. Press the RESET button
twice to perform a hard reset and return to the Run Mode.
In the Peak Mode, press the RESET button to reset peak values. The meter shows
and returns to the Run
Mode.
In the Setpoint Mode, press the RESET button to reset the latched setpoint. The meter shows
and enters
the Run Mode.
In the Tare Mode, press the RESET to reset. The meter shows
.
When in setpoint or Configuration Mode, if the meter shows 9999 or –1999 with all flashing digits, the
value has overflowed. Press the
S/NT/GRS button to start a new value.
2.5 Back of the Meter
Figure 2-3 shows the label describing the connectors on the back of the meter. Table 2-2 on the following page
gives a brief description of each connector at the back of the meter.
Figure 2-3 Connectors (AC-Powered and DC-Powered Detail)