0 setpoint configuration displays, 0 specifications – Cooper Instruments & Systems DFI Infinity CS Economy Digital Indicator User Manual
Page 31
![background image](/manuals/600669/31/background.png)
DFI INFINITY CS (V- M3598/N/0906)
28
CF 70
Table 6-2 Run Mode Displays
Display
X/TARE
S/NT/GRS RESET Description
/
Displays NET or GROSS
reading. Once reading shows,
respective value shows.
Peak Reading
Toggle between Net and Gross
values.
Press to
activate
Will reset your
tare when
viewing this
function
Tare Reset
Reset Latched Alarms
Pressing the RESET button
resets your latched alarm
7.0 SETPOINT CONFIGURATION DISPLAYS
Table 7-1 Setpoint Configuration Displays
MENU
X/TARE
S/NT/GRS Description
Press to scroll to the
next digit to the right
Press to change the
value of the flashing
digit
SETPOINT 1
Select from –1999 through 9999
Press to scroll to the
next digit to the right
Press to change the
value of the flashing
digit
SETPOINT 2
Select from –1999 through 9999
8.0 SPECIFICATIONS
SIGNAL INPUT
Input Ranges:
0-100mV, ± 50 mV, 0-10 V, ± 5 V, 0-20 mA, 4-20 mA
Isolation:
Dielectric strength to 2500V transient per 3mm spacing based on EN 61010 for
260Vrms of DC working Voltage
Noise Rejection:
Normal Mode Rejection (NMR) = 60dB
Common
Mode
Rejection
(CMR)
=
120dB
Resistance:
100 Meg ohms for 100 mV or ±50 mV input range
1 Meg ohm for 10 or +5 V input range
5 ohms for 20 mA current input range
Big Display
:
4-digit, three color programmable 9-segment, LED 21 mm (0.83”)
Symbol:
(-1.9.9.9 ~ 9.9.9.9)
Standard Display:
4-digit, 14-segment LED, 13.8 mm (0.54”)
Symbol:
(-1.9.9.9 ~ 9.9.9.9.)
ANALOG TO DIGITAL
Technique:
Dual
slope
Internal resolution:
15 bits
Read Rate:
3/sec Polarity Automatic