Bio-Rad BioLogic LP System User Manual
Page 79
72
System Operation
Figure 29. Programming: the Fraction Collector’s Threshold with Collection Windows Mode
(Screen displays are keyed to the discussion in Table 21)
Window Start (ml) End Frac (ml) Th (AU)
>01
0.0
1.00
1.00
1.000
02 New collection window to be added
INSERT
EDIT
DELETE
OK
Window Start (ml) End Frac (ml) Th (AU)
01
0.0
1.00
1.00
1.000
>02 New collection window to be added
ADD
OK
Method:
Time: 1.00 ml
Window: 1
Start: 0.00 ml
End: 0.00 ml
(start)
END
CANCEL
OK
Method:
Time:
1.00 ml
Window: 1
Fraction Size: 1.00 ml
CANCEL
OK
Method:
Volume:
2.00 ml
Window: 1
Thresh: 2.0000 AU
Bubble Filter: Medium
SET BF
CANCEL
OK
Method:
Volume: 1.00 ml
Select a Fraction Collector Mode
ALL THRESHOLD
WINDOWS
THRES+WIN
Low/Med/Hi/Off
F1
F5
F5a
F5b
F5c
(return
to FT, Table 17)
(return to F5)
(return to F1)
(return
to F5)
(return
to F5)
F5
FRACTION COLLECTION TABLE FOR THRESHOLD + WINDOWS MODE
F5a
START AND END TIMES FOR WINDOW
F5b
FRACTION SIZE FOR WINDOW
F5c
THRESHOLD FOR WINDOW
LEGEND:
THRESHOLD AND WINDOWS MODE
To remove Method's fraction collection
mode; no fraction collection will occur
when the Method is run.
Method: name
Volume:
2.00 ml
FC Mode: Collect all
Estimated Number of Fractions: 20
EDIT
ERASE
NEW MODE
OK
- S3e™ Cell Sorter (36 pages)
- S3e™ Cell Sorter (132 pages)
- xMark™ Microplate Absorbance Spectrophotometer (20 pages)
- iMark Microplate Absorbance Reader (112 pages)
- Microplate Manager Software (138 pages)
- iMark Microplate Absorbance Reader (48 pages)
- Model 550, Ultramark, and Benchmark Microplate Reader Accessories (39 pages)
- Model 550, Ultramark, and Benchmark Microplate Reader Accessories (15 pages)
- Model 680 Microplate Reader Accessories (150 pages)
- Model 550, Ultramark, and Benchmark Microplate Reader Accessories (31 pages)
- Model 680 Microplate Reader Accessories (68 pages)
- Mouse Typer Isotyping Kit (14 pages)
- ZOE™ Fluorescent Cell Imager (36 pages)
- TC20™ Automated Cell Counter (34 pages)
- Design Your NGC™ System (306 pages)
- Design Your NGC™ System (300 pages)
- ChromLab™ Software (178 pages)
- BioLogic DuoFlow 10 System V9-8 (4 pages)
- BioLogic DuoFlow 10 System HR Gradient Pump Maintenance Kit (4 pages)
- BioLogic DuoFlow 10 System DuoFlow Chromatography System Version 4.0 Software New Features (7 pages)
- BioLogic DuoFlow 10 System DuoFlow Chromatography System Starter Kit (40 pages)
- BioLogic DuoFlow 10 System DuoFlow Chromatography System 5.0 Software New Features (6 pages)
- BioLogic DuoFlow 10 System pH Monitor (4 pages)
- BioLogic DuoFlow 10 System Chromatography System (239 pages)
- BioLogic Mixers (2 pages)
- BioLogic QuadTec™ Detector and Components (58 pages)
- BioLogic Sample Loading Loops (20 pages)
- BioLogic LP System (1 page)
- LP Data View Software for BioLogic LP System (5 pages)
- LP Data View Software for BioLogic LP System (4 pages)
- BioLogic LP System (28 pages)
- BioLogic LP System (5 pages)
- Model EP-1 Econo Pump (1 page)
- Model EP-1 Econo Pump (23 pages)
- Econo Gradient Pump Kits (19 pages)
- Econo Gradient Pump Kits (51 pages)
- Model EP-1 Econo Pump (27 pages)
- Profinia™ Protein Purification Instrument (4 pages)
- Profinia™ Protein Purification Instrument (2 pages)
- Profinia™ Protein Purification Instrument (224 pages)
- Profinia Protein Purification System Accessories (1 page)
- Profinia Protein Purification System Kits (24 pages)
- Profinia Protein Purification System Kits (24 pages)
- Profinia Protein Purification System Buffers and Reagents (4 pages)