beautypg.com

B&G H2000 Pilot *DISCONTINUED* User Manual

Page 34

background image

HB-0844-04

2-15

Damping control for any of the other functions that can be damped is
achieved in a similar manner.

2.6

EXAMPLES OF CALIBRATION

The calibration method of your Hydra 2000 System will be made clear by the
following examples. The Calibration Process is described in detail in Part 3 -
Calibration.

2.6.1

Calibration Adjustment - Boat Speed

(1) Using the Scroll Up or Scroll Down Keys select the upper or
lower display as required.

(2) If BOAT SPD (or STD LOG) is shown in the upper display,
press and hold the Scroll Down Key to select CALIBRATE from
the menu. If BOAT SPD (or STD LOG) is in the lower display use
Scroll Up.

(3) Press Enter and then press Scroll Down to select MANL CAL
on the Display.

(4) Press Enter and SINGLE is shown on the Display.

Notes:

1. SINGLE is the choice required if a single paddlewheel or sonic

sensor is fitted.

2. If two paddle-wheels or two sonic sensors are fitted, the Scroll

Up or Scroll Down Keys should be used to select PORT CAL
or STBD CAL as required.

(5) Press Enter to reveal the current calibration value in Hz/knot.

(6) To adjust the calibration value, press Enter and the value
flashes.

(7) Using the Scroll Up and Scroll Down Keys to change the
calibration value as required to the new calibration value.

(8) Press Enter to input the new calibration value into the system.

(9) Press Page to return to the normal display.