background image

68

YP1225 and 1625

Great Plains Manufacturing, Inc.

401-226M

07/09/2009

Hydraulic
marker
functioning
improperly

Air or oil leaks in hose fittings or con-
nections.

Check all hose fittings and connections for air or oil leaks.

Low tractor hydraulic oil level.

Check tractor hydraulic oil level.

Loose or missing bolts or fasteners.

Check all bolts and fasteners.

Needle valve plugged.

Open needle valve, cycle markers slowly and reset needle
valve, refer to page 41.

Needle valve(s) in sequence valve
plugged.

Open needle valves, cycle markers slowly and reset needle
valves, refer to page 41.

Marker disk
does not
mark

Marker folding linkage does not have
enough slack to allow marker disk to
drop into field depressions.

Maximum down float should be limited by the slot at the rod
end of the marker cylinder, refer to page 41.

Reverse marker disk to pull or throw dirt.

Planter does
not fold or
unfold fully

Fold cylinders out of phase.

Rephase cylinders, refer to page 31

Bleed fold circuit, refer to page 15

Problem

Cause

Solution