beautypg.com

Great Plains YP1625 Operator Manual User Manual

Page 102

background image

98

YP1225 and 1625

Great Plains Manufacturing, Inc.

401-226M

07/09/2009

Refer to Figure 105
11. Enter your planned planting speed using Up/Down

arrow keys. Calibration mode will not accept a speed
higher than 10 mph. Press Function key to advance
to next window.

Refer to Figure 106
12. Enter the amount of seed you want to measure. For

volumetric metering, this should be at least

1

4

of a

pound. For singulated metering, at least 100 seeds
should be selected. Press Function key to advance
to next window.

Refer to Figure 107
13. The cab console informs you of the length of time

that the drive will be operating, in order to meter the
amount of seed you have requested, at the calibra-
tion number, drill width, and number of rows you
have selected. Press Function key to advance to
next window.

Refer to Figure 108
14. If the screen reads TIME TOO LOW, or TIME TOO

HIGH, you will need to change the amount of seed
that you will count or measure. For calibration accu-
racy, the Controller firmware will not allow you to cal-
ibrate at settings that would result in the drive
rotating for less than 4 seconds, or more that 255
seconds. Press Function key to advance to next win-
dow.

Figure 105

Cal. Mode Speed

22721

Figure 106

Cal. Mode Seed Target

22780

Figure 107

Cal. Mode Time Window

22781

Figure 108

Cal. Mode Time Limit Error

22782