Console functions, Calibration, Console functions calibration – Great Plains YP1625 Operator Manual User Manual
Page 100

96
YP1225 and 1625
Great Plains Manufacturing, Inc.
401-226M
07/09/2009
Console Functions
Refer to Figure 98
The use of each key is as follows:
• On/VR key-turns drive system on. Press twice for VR
mode. Note: Engage key must also be pressed to start
drive operation.
• Off key: used to shut off Console.
• Function key: used in calibration mode and to program
Console for VR recipes.
• Up/down arrow keys: used to change rates manually,
to set calibration numbers, and VR controller options.
• Engage key: press to start drive.
Note: Drive will not run unless light above key is illuminat-
ed.
Note: Figure 98 shows Main Operating Screen in manual
mode.
Calibration
Turn on Controller Console by pressing On/VR key.
Green light above On/VR key will illuminate when
power is on. Adjust desired planting rate by using the
Up/Down arrow keys to change the Set rate.
2.
Set the desired Rate by using the Up/Down arrow
keys.
Press Function key until Calibration Number window
appears.
4.
Select drive calibration number based on row spac-
ing and metering wheel, from chart. See “Planting
Calibration” on page 105.
5.
Use Up/Down arrow keys to set Calibration number.
Figure 98
Veris Key Functions
22710
Figure 99
Initiate Calibration
22715
Figure 100
Calibration Number Prompt
22778