6.10.F–Hard Power and Remote Unlock (91-) with Forced/Propped Door (DM-)
Installation
1. ElectroLynx
®
System Wiring Instructions (refer to Fig. 1 and Fig. 4)
a. Look for the mating part on ASSA ABLOY doors & frames. Then plug in all connectors as shown in
Fig. 4 during product installation
b. Hard wire forced/propped, hard power and/or remote unlock (REX), as shown
2. Non-ElectroLynx
®
System Wiring Instructions (refer to Fig. 1 and Fig. 4map)
a. Cut the 8-pin connector off the Remote Power/Unlock harness and hard wire to non-ElectroLynx
®
door harness. Remote power requires three conductors and remote unlock requires two conductors.
b. Hard wire door harness to power transfer device
c. Hard wire forced/propped, hard power and/or remote unlock (REX), as shown