39

FACTORY DEFAULT

OPTION

NUMBER

OPTION

1PHASE 3FHASE

DIPSLAY

FORMAT

4

MINIMUM SELECTABLE AMPERAGE. .
Minimum selectable amperage is the lowest amperage value
that the user is capable of setting in SMAW, Lift GTAW, and
GTAW local mode. This feature is effective when the user would
like to insure that the amperage is never set below a particular
amperage level. The range of values permitted is 5-275 amps
(single phase) and 5-400 amps (three phase). The minimum
selectable amperage is never permitted to be set greater than
the maximum selectable amperage.

5 5 XX4

5

MAXIMUM SELECTABLE VOLTAGE. .
This voltage is largest value that the user is capable of setting
in GMAW local welding mode. Voltages above this value can
not be entered by the user in local mode. This voltage value can
be exceeded in remote by using a feeder with voltage setting
capability. The range of values permitted is 10-31 volts (single
phase) and 10-36 volts (three phase). The maximum selectable
voltage is never permitted to be set less than the minimum
selectable voltage.

31.0 36.0 XX5

6

MINIMUM SELECTABLE VOLTAGE. .
This voltage is the lowest value that the user is capable of
setting in GMAW local welding mode. Voltage below this value
can not be entered by the user in local mode. This voltage value
can be overridden in remote by using a feeder with voltage
setting capability. The range of value permitted is 10-31 volts
(single phase) and 10-36 (three phase). The minimum
selectable voltage is never permitted to be set greater than the
maximum selectable voltage.

10.0 10.0 XX6

7

MAXIMUM SELECTABLE REFERENCE. .
This reference is the largest value that the user is capable of
setting in Pulsed GMAW local welding mode. Reference above
this value can not be entered by the user in local mode. The
reference value can be exceeded in remote by using a feeder
with voltage setting capability. The ranges of value permitted
are between 0 and 440 in increments of 1. The maximum
selectable reference is never permitted to be set less than the
minimum selectable reference.

440 440

XX7