Tweco 400 MSTP Arcmaster User Manual
Page 28

22
3.
Positive Terminal
Welding current flows from the Power Source via heavy duty Dinse type terminal. It is essential, however, that the
male plug is inserted and turned securely to achieve a sound electrical connection.
4.
Negative Terminal
Welding current flows from the Power Source via heavy duty Dinse type terminal. It is essential, however, that the
male plug is inserted and turned securely to achieve a sound electrical connection.
CAUTION 2
Loose welding terminal connections can cause overheating and result in the male plug being fused in the
bayonet terminal and /or melting of the housing (case).
5.
Remote Control Socket
The 19 pin Remote Control Socket is used to connect remote current control devices to the welding Power Source.
To make connections, align keyway, insert plug, and rotate threaded collar fully clockwise.
Socket Pin
Function
A
Contactor circuit (+15 Volts)
B
Contactor circuit in, (closure between pin A and Pin B will energize output.)
C
Scaled output voltage signal: Vfb = 10 Arc Volts/Volt
D
24 VAC auxiliary power high side
E
115 VAC auxiliary power high side
F
24/115 VAC neutral
G Chassis
ground
H
Remote control maximum
J
Remote control wiper (0 – 10 Volts)
K
Remote Control minimum
L Control
circuit
common
M
Arc Establish = +12 Volts
N
Control Circuit common
P
24 VAC auxiliary power high side
R
24/115 VAC neutral
S N/C
T N/C
U
Scaled output signal: Ifb = 100 Amps/Volt
V N/C
6.
ON/OFF Switch
This switch connects the Primary supply voltage to the inverter when in the ON position. This enables
the Power Supply.