16

2.05.02 Input Power

Each unit incorporates an INRUSH circuit and input voltage sensing circuit. When the MAIN SWITCH is
turned ON, the inrush circuit provides a pre-charging of the input capacitors. SCR’s in the Power Control
Assembly (PCA) will turn ON after the input capacitors have charged to full operating voltage (after
approximately 5 seconds).

Note 5

Note the available input power. Damage to the PCA could occur if 575VAC or higher is applied.

The following 208-230/460V Primary Current recommendations are required to obtain the maximum welding
current and duty cycle from this welding equipment:

Current & Duty Cycle

Model

Primary Supply

Lead Size

Minimum Primary

Current Circuit Size

(Vin/Amps)

MIG TIG STICK

208/63

- -

230/57

- -

460/29

400A @

25%

-

-

208/49

- -

230/44

-

-

460/22

-

400A @

25%

-

208/67

- -

230/61

- -

8/4 AWG minimum

(Factory Fitted)

3

Phase

460/31

- -

400A @ 25%

208/88

- -

230/79

300A @

25%

-

-

208/67

- -

230/60 -

300A @

25%

-

208/97

- -

ARC

MASTER

400 MSTP

8/3 AWG minimum

1

Phase

230/87 - -

300A @ 25%

Table 2 – Primary Current Circuit sizes to achieve maximum current