Tweco 400 MSTP Arcmaster User Manual
Page 22

16
2.05.02 Input Power
Each unit incorporates an INRUSH circuit and input voltage sensing circuit. When the MAIN SWITCH is
turned ON, the inrush circuit provides a pre-charging of the input capacitors. SCR’s in the Power Control
Assembly (PCA) will turn ON after the input capacitors have charged to full operating voltage (after
approximately 5 seconds).
Note 5
Note the available input power. Damage to the PCA could occur if 575VAC or higher is applied.
The following 208-230/460V Primary Current recommendations are required to obtain the maximum welding
current and duty cycle from this welding equipment:
Current & Duty Cycle
Model
Primary Supply
Lead Size
Minimum Primary
Current Circuit Size
(Vin/Amps)
MIG TIG STICK
208/63
- -
230/57
- -
460/29
400A @
25%
-
-
208/49
- -
230/44
-
-
460/22
-
400A @
25%
-
208/67
- -
230/61
- -
8/4 AWG minimum
(Factory Fitted)
3
Phase
460/31
- -
400A @ 25%
208/88
- -
230/79
300A @
25%
-
-
208/67
- -
230/60 -
300A @
25%
-
208/97
- -
ARC
MASTER
400 MSTP
8/3 AWG minimum
1
Phase
230/87 - -
300A @ 25%
Table 2 – Primary Current Circuit sizes to achieve maximum current