beautypg.com

Tweco 400 MSTP Arcmaster User Manual

Page 38

background image

32

4.01 Stick Welding

• Connect work lead to negative terminal
• Connect electrode lead to positive terminal
• Switch machine on
• Set weld current
• Set Contactor
• Connect remote control device if required

Use the Scroll Buttons to move to the parameter to be set. The LED will show which function is being
adjusted on the weld sequence graph. Use the control knob to adjust each parameter.
• Set

HOT START

• Set

ARC CONTROL

• Set

WELD

current

Commence welding


4.02 LIFT TIG Welding

• Connect work lead to positive terminal
• Connect TIG torch to negative terminal
• Switch machine on
• Set weld current
• Connect remote control device if required

Use the Scroll Buttons to move to the parameter to be set. The LED will show which function is being
adjusted on the weld sequence graph. Use the control knob to adjust each parameter.

Commence welding