N7500 system operation – Tweco N7500 User Manual
Page 42

SYSTEM OPERATION
5-6
Manual 89250890
N7500
SYSTEM OPERATION
9. Use the up or down “Mode Selector”
or
buttons to scroll to “Travel Delay.” See “Figure 5-9: Travel
Delay Screen.”
Press the “OK”
OK
button and rotate the potentiometer dial
to adjust the time delay for any time
length between 0 and 6.0 seconds.
Press the “OK”
OK
button to set the Travel Delay time setting.
ART# A-10828_AB
Menu Setting
Travel Delay
Parameter Guide
Voltage
42.0V
Figure 5-9: Travel Delay Screen
Travel Delay Setting
Approximate
Setting
Electrode Size
Target Depth
Inches
mm
0.0
5/16” (7.9 mm) through 3/4” (19.05 mm)
1/8
3.2
0.5
5/16” (7.9 mm) through 3/4” (19.05 mm)
1/4
6.4
1.0
5/16” (7.9 mm) through 3/4” (19.05 mm)
5/16
7.9
1.5
3/8” (9.53 mm) through 3/4” (19.05 mm)
3/8
9.5
2.0
1/2” (12.7 mm), 5/8” (15.88 mm), 3/4” (19.05 mm)
1/2
12.7
2.5
5/8” (15.88 mm), 3/4” (19.05 mm)
5/8
15.9
3.0
3/4” (19.05 mm)
11/16
17.5
3.5
3/4” (19.05 mm)
3/4
19.0
4.0
3/4” (19.05 mm)
7/8
22.2
Table 5-10: Travel Delay Setting
10. Use the up or down “Mode Selector”
or
buttons to scroll to “No Current Detect”. See “Figure
5-11: No Current Detect screens“.
The N7500 System contains a “No-Current Detect” circuit. This circuit monitors Arc Current. Should the
arc increase or decrease outside set limits or the arc stop, the “No-Current Detect” circuit will shut down
the gouging sequence. “Normal” mode is preset from the factory.
This program can be set for one of three response levels:
NORMAL - Setting provides 0.4 second System shutdown delay.
SPECIAL - Setting provides 0.8 second System shutdown delay.
OFF - System continues to operate regardless of Arc Current level. System shutdown is manually
controlled.