Ultra-cut 300 xt, 06 connect input power and ground cables – Tweco 300 XT Ultra-Cut Plasma Cutting System User Manual
Page 29

ULTRA-CUT 300 XT
Manual 0-5274
INSTALLATION
3-5
3.06 Connect Input Power and Ground Cables
Connect Input Power and System Ground Cables
1. Remove the input power cover to the right of the coolant filter at the rear of the power supply. To do this
remove the two screws then lift up and pull away.
2. Carefully cut back the outer sheath on the primary input power cable to expose the individual wires. Cut
back the insulation on the individual wires. Route the cable upward through Input Power Port at the bottom
of the panel. There are 2 extra plates included at the cable entrance. Discarding one or both allows changing
the opening size for larger cable/strain relief.
3. Install stripped end of 3 phase wires into the terminal block L1, L2 and L3 and connect the individual cables
as shown.
4. Connect the power cable ground wire to the ground terminal block.
5. Route a system ground cable (F1) through the last opening in the connections cover support panel next to
the input power cable. Connect the cable to the ground terminal block on the power supply rear panel.
Refer to the Ground Connections Section for full details and procedures on proper system grounding.
Input Power
Ground Terminals
Art # A-11970
F1 Ground