Ultra-cut 300 xt – Tweco 300 XT Ultra-Cut Plasma Cutting System User Manual
Page 156

ULTRA-CUT 300 XT
�50
PPENDIX
Manual 0�5�7�
Reasons why RAS Control relay would not close:
6. Pilot current flowing. There actually is pilot current flowing somewhere. Unlikely as it would normally set
the �08 fault but we have to rule it out.
a. Disconnect J�1 on the Pilot board, if HF still doesn’t fire and the Relay board Pilot LED, D11, is still
on, it’s due to a fault in the detection circuits.
7. Faulty detection circuit. There isn’t any pilot current but a fault in the circuits measuring pilot current is
indicating there is current.
a. Measure between pins 8 (�) and 9 (+) on the Pilot ribbon cable from Relay board J3 to Pilot board J��. If
there is no pilot current it should be zero. nything else indicates the Pilot board current sensor is faulty
causing the Relay board D11 to be on. Replace the Pilot board assembly.
b. If the Pilot current signal on the pilot ribbon cable was zero, measure between pins �3 (�) and �5 (+) on
the �0 pin ribbon cable between the Relay board and the CCM. This would also normally be zero if there
is no pilot current. nything else would indicate the Relay board is faulty.
Art # 12307
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
J23
TO RELAY BOARD
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
J4
From I/O PCB
24VDC_SW
D21
GREEN
D23
RF ON
1
5
3
4
K2
RAS CONTROL
120
VA
C
120 VAC to RAS
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
J8
120
VA
C
R
ET
120 VAC_1
From J9-1
120 VAC_RET
From J9-7
CCM I/O Board
Relay & Interface Board
1
2
3
4
5
6
7
8
9
10
11
12
13
14
J59 - RAS
(98)
(99)
T2
120 / 6000 VAC
(98)
(99)
6.5K 1W
6.5K 1W
AC200XT only
(Rear Panel)
TP1
GND
TP1
GND
/ RAS ON
8. If “ /RS ON” signal is low on pin 16 of the �0 pin ribbon cable, relative to TP1 on the CCM I/O board,
during the ignition time then we need to determine if the Relay board is defective. If /RS ON signal is
not low the CCM or the �0 pin ribbon cable may be defective.
a. If the Relay board RF ON LED, D�3, is not on while the /RS ON signal is low, then the Relay board is
defective.
b. Is D�3 is on, measure for 1�0 VC on J8�3 to J8�11. If not present the Relay board is defective.
c. If 1�0 VC is present at J8 during the ignition time go back and perform steps ���.