7.05 Coolant Leak Trouble-Shooting

Never operate the system if coolant leaks from the torch. A steady drip indicates that torch parts are damaged or

installed improperly. Operating the system in this condition can damage the torch head. Refer to the following

chart for guidance on coolant leakage from the torch head.

No

Yes

Yes

Are Parts New

or Used?

Are Parts fully

assembled into

the Torch?

Unsure?

Disassembly fully

and re-assemble

the Torch Properly.

See Installation Manual.

Replace Torch Head

Is the Torch Damaged?

Replace Consumable

Cartridge and Shield Cup.

Torch still leaks?

Remove and Lubricate

all O-rings on Torch Head,

Consumables Cartridge,

and Consumables.

Re-assemble Torch.

Still leaks?

The parts probably are worn out.

See chart for approximate life expectancy.

The torch may be damaged. See page

to determine if head damage has occurred.

Order Coolant

Tube Replacement Kit

Leaking from

Coolant Supply or

Coolant Return?

Yes

Yes

Yes

No

Return

Supply

Used

Order Coolant

Check Valve

Kit 9-4846

New

Torch leaks

Are Torch

Consumable Parts

Installed?