Ultra-cut 300 xt, 06 specifications & electrical requirements – Tweco 300 XT Ultra-Cut Plasma Cutting System User Manual
Page 18

ULTRA-CUT 300 XT
2-2
SPECIFICATIONS
Manual 0-5274
2.06 Specifications & Electrical Requirements
300 Amp System
Ultra-Cut 300 XT™ Specifications & Design Features
Max OCV (U0)
425 vdc
Minimum Output Current
5 Amps
Max Output Current
300 Amps
Output Voltage / IEC
60 - 180 vdc / 60 - 200 vdc
Duty Cycle Rating
100% @ 300A, 200V, (60kW),
Ambient Temperature
for Duty Cycle Rating
104F° (40°C)
Operating range
14°F to 122°F (-10°C to + 50°C)
Power Factor
0.94 @ 300 A DC Output
Cooling
Coolant and Forced Air (Class F)
Ultra-Cut 300 XT™ Power Supply
Input
Power Input
Current
Suggested Sizes (See Note)
Voltage
Freq.
3-Ph
3-Ph
Fuse (Amps) Wire (AWG) Wire (mm
2
)
(Volts)
(Hz)
(kVA)
(Amps)
3-Ph
3-Ph
3-Ph
480
50/60
63
77
150
#4
25
IEC
480
50/60
72
88
150
#4
25
NOTE
* Suggested wire size based on United States NFPA 70 National Electrical Code 2011 edition published by the
National Fire Prevention Association. Listings are from table 400.5(A)(2) for flexible cord of certain types rated
for 75 deg � in ambient temperat�res �p to �0 deg �. �sing �ires of lo�er temperat�re rating or di� erent ins��
deg � in ambient temperat�res �p to �0 deg �. �sing �ires of lo�er temperat�re rating or di� erent ins��
� in ambient temperat�res �p to �0 deg �. �sing �ires of lo�er temperat�re rating or di�erent ins��
lation type may require larger wire size. De rate for higher ambient.
These are s�ggestions only. Al�ays refer to yo�r local and national codes that apply to yo�r region for final
determination of correct wire type and size.