Troubleshooting 6-12 Manual 0-5171

CUTMASTER 42

TROUBLESHOOTING

DC Bus Testing

Multimeter Lead Placement

Voltage with Supply voltage ON

Upper capacitor bank

Positive meter lead to testpoint 30

Negative meter lead to testpoint 29

192 VDC +/-10%

Lower capacitor bank

Positive meter lead to testpoint 31

Negative meter lead to testpoint 32

192 VDC +/-10%

Overall capacitor bank

Positive meter lead to testpoint 29

Negative meter lead to testpoint 32

384 VDC +/-10%

Table 6-5 DC BUS, Multimeter set to measure DC volts

Note: These DC voltages are at nominal mains supply voltage of 240VAC.