beautypg.com

12 check main input rectifier, 13 dc bus voltage measurement, Cutmaster 42 troubleshooting – Tweco 42 CutMaster Service Manual User Manual

Page 46

background image

Troubleshooting 6-10 Manual 0-5171

CUTMASTER 42

TROUBLESHOOTING

6.12 Check Main Input Rectifier

DC—

AC1

AC2

DC+

Art # A-10291

Input Rectifier Testing

Multimeter Lead Placement

Diode Voltage

AC1 to DC+

Positive meter lead to AC1

Negative meter lead to testpoint DC+

0.2 – 0.8 VDC

AC2 to DC+

Positive meter lead to AC2

Negative meter lead to testpoint DC+

0.2 – 0.8 VDC

AC1 to DC-

Positive meter lead to testpoint DC-

Negative meter lead to testpoint AC1

0.2 – 0.8 VDC

AC2 to DC-

Positive meter lead to testpoint DC-

Negative meter lead to testpoint AC2

0.2 – 0.8 VDC

Table 6-4 IGBT’s, Multimeter set to measure Diode Voltage

Measurements may be made directly onto the main input rectifier. AC1 and AC2 may be measured from the pins on

the mains supply plug with the main power switch set to the ON position.

6.13 DC Bus Voltage Measurement

Apply voltage to the Power Source.

There are extremely dangerous voltage and power levels present inside these Power Sources. Do

not attempt to diagnose or repair unless you have had training in power electronics measurement and troubleshoot-

ing techniques.
Once power is applied to the Power Source, there are extremely hazardous voltage and power levels present.
Do not touch any live parts.