Powers e420U Series Under-the-Counter Thermostatic Tempering Valves User Manual
Page 4

DIMENSIONAL DATA
CHECKSTOPS
© February 2001 Powers, a Watts Industries Co.
3400 Oakton Street, Skokie, IL 60076 Phone: 800.669.5430 • 847.673.6700 • Fax: 847.673.9044
www.powerscontrols.com
5435 North Service Road, Burlington, Ontario, L7L 5H7 Canada • Phone: 888.208.8927 • Fax: 888.882.1979
WARRANTY INFORMATION
Powers warrants that the equipment manufactured by it is free from defects in material and workmanship and, without charge, equipment
found to be defective in material and workmanship will be repaired, or at Seller’s option, replaced F.O.B. original point of shipment, if writ-
ten notice of failure is received by Seller within one (2) years after date of shipment, provided said equipment has been properly installed,
operated in accordance with Seller’s instructions, and provided such defects are not due to abuse or chemical decomposition by chemical
or galvanic action. This express warranty is in lieu of and excludes all other warranties, guarantees, or representations, express or implied.
There are no implied warranties of merchantability or of fitness for a particular purpose. The Seller assumes no responsibility for repairs
made on Seller’s equipment unless done by Seller’s authorized personnel, or by written authority from the Seller. The Seller makes no guar-
antee with respect to material not manufactured by it.
SERVICING
1. Remove four bonnet screws (16) and pull out bonnet assem-
bly. The motor should come out with the bonnet. If not, it
can easily be pulled out.
2. Remove the cartridge with tool (supplied) and a screwdriver
or pliers.
Before disassembling valve piping, turn off valve and the
supply water upstream.
TIE420U
Page 4
3. Reassemble the valve in reverse order.
4.IMPORTANT: After completing any maintenance/repairs,
check maximum discharge temperature. Adjust if neces-
sary.
Form TIE420U 0218
EDP# 6508935