Powers 215 Series TempTAP Lead Free Gooseneck Thermostatic Faucets User Manual
T emp tap, English instructions, Warranty
ENGLISH INSTRUCTIONS
Warranty
n
The Seller w
arrants that the equipment manufactured by it and co
vered by this
order or contract is free from defects in material and workmanship and, without
charge, equipment found to be defecti
ve in material or workmanship will be
repaired, or at Seller
’s option replaced F
.O.B. original point of shipment, if writ
ten
notice of failure is received by S
eller within one (1) year after date of shipment
(unless specifically noted elsewhere), provided said equipment has been properly
installed, operated in accordance with the Seller
’s instructions, and pro
vided such
defects are not due to abuse or decomposition by chemical or g
alvanic action.
ThiS
expreSS
w
arranTy i
S in lieu
OF and exclude
S all
OTher
warran
-
Tie
S, guaran
Tee
S,
Or repre
Sen
TaT
iO
nS
, expreSS
OF
implied. There
are
nO
implied w
arranTie
S O
F merchanTa
Bili
Ty
Or
OF F
iT
neSS
FO
r a p
ar-
Ticular purp
OSe.
The S
eller assumes no responsibility for repairs made on the
Seller
’s equipment unless done by the S
eller’s authoriz
ed personnel, or by writ
ten
authority from the Seller
. The S
eller makes no guarantee with respect to material
not manufactured by it.
Garantía
n
el V
endedor garantiza que los equipos fabricados por él y cubier
tos por esta orden
o co
ntrat
o está
n lib
res d
e def
ectos
en l
os ma
terial
es y m
ano
de ob
ra y
que l
os
equipos con materiales o mano de obra defectuosos serán reparados sin cargo
o, a opción del Vendedor
, reemplazados F .O
.B. en el punto original de envío, si
el Vendedor recibe una notificación por escrito de falla en el lapso de un (1) año
después de la fecha de en
vío (a menos que se especifique en otra parte), siempre
y cuando dichos equipos hayan sido cor
rectamente instalados y utilizados de
conformidad con las instrucciones del Vendedor
, y siempre que dichos defectos
no se
deban a
maltrato o
descomposición por
acción química
o galvánica.
e
STa
garanTÍ
a expre
Sa
reempla
Za
y
excluye cual
Quier
OT
ra garan
TÍa
,
garanTÍ
a gra
Tui
Ta
O pr
Ome
Sa
, expre
Sa
S O impl
Íci
Ta
S. n
O exi
ST
en
garanTÍ
aS
implÍci
Ta
S de
c
Omerciali
Za
ciÓ
n O
de id
Oneid
ad p
ara un
prO
pÓS
iT
O en
par
Ticular
. e
l Vendedor no asume ninguna responsabilidad
por las reparaciones hechas a los equipos del
Vendedor salv
o que se realicen por
personal autorizado por el
Vendedor o con autorización escrita del
Vendedor
. e
l
Vendedor
no otorg
a ninguna garantía
con respecto a
los materiales no
fabricados
por él.
Garantie
n
le vendeur g
arantit que l'équipement fabriqué par lui et couvert en ver
tu de
cette commande ou de ce contrat est exempt de vices de matériau et de fab
-
rication et, dans l'éventualité ou de tels vices de matériau ou de fabrication
se manifesteraient, il sera réparé sans frais ou, à la discrétion du vendeur,
remplacé franco à bord (Fa
B) de son point d'expédition d'origine (sauf si
spécifié ailleurs), pourvu que ledit équipement ait été installé cor
rectement
et utilisé conformément au
x instructions du vendeur et, pour
vu que
de tels
vices ne soient pas le résultat d’une utilisation abusive ou d'une décom
-
po
sit
ion
d
éco
ula
nt
d'u
ne
réa
cti
on
ch
im
iq
ue
ou
g
alv
an
iq
ue.
la
p
rÉ
Se
nT
e
garanTie
e
ST
expreSS
e, rempla
ce e
T exclu
T TO
uT
e a
uT
re garan
Tie
Ou
repr
ÉSen
Ta
TiO
n expre
SSe
Ou
implici
Te
. il
n
’exi
ST
e a
ucune
garanTie
Ta
ciT
e de
Quali
TÉ marchande
Ou
d
’ ad
apTa
TiO
n À
un B
uT
par
Ticulier
. le vendeur n
’assume aucune responsabilité pour des répara-
tions effectuées sur son équipement à moins qu'elles aient été ef
fectuées par
du personnel autorisé par lui ou par une autorisation écrite de lui.
le vendeur
n’of
fre aucune garantie pour les matériaux non fabriqués par lui.
USA: Phone:
1.800.669.5430
•
Fax 1.
847.229
.0526
•
www.powerscontrols.com
Canada: Phone:
1.888.208.8927
•
Fax 1
.88
8.479
.2887
•
www.powerscontrols.ca
IS-P-205_215 1314
EDP# 6512326
© 2013 Powers
USA: Phone:
1.800.669.5430
•
Fax 1.
847.229
.0526
•
www.powerscontrols.com
Canada: Phone:
1.888.208.8927
•
Fax 1
.88
8.479
.2887
•
www.powerscontrols.ca
IS-P-205_215 1314
EDP# 6512326
© 2013 Powers
USA : Phone:
1.800.669.5430
•
Fax 1.
847.229
.0526
•
www.powerscontrols.com
Canada : Phone:
1.888.208.8927
•
Fax 1
.88
8.479
.2887
•
www.powerscontrols.ca
IS-P-205_215 1314
EDP# 6512326
© 2013 Powers
Specifications
n
Connections .......................................................... 3/8" compression inlets with
checks
Maximum Operating Pressure .......................... 125psi (861 kPa)
Maximum Hot Water Temperature ................... 194°F (90°C)
Minimum Hot Water Supply Temp. ................... 5°F (3°C) Above Set-Point
Temperature Adjustment Range ....................... 60 - 120°F (15 - 49°C)
Minimum Flow ........................................................ 0.5 gpm (2.2 lpm)
Cold Water Inlet Temperature Range ............... 39 - 80°F (4 - 27°C)
Hot Water Inlet Temperature Range ................. 120 - 180°F (49 - 82°C)
Listing ..................................................................... ASSE 1070, IAPMO cUPC
Approval Standards ............................................. ASSE 1070, CSA B125.3,
NSF 61 Section 9 Annex G
Installation Instructions
n
1. Flush all piping thoroughly before installing.
2. The installation and field adjustment of TempTAP
™
faucet is the responsibility of the
installer and shall be carried out in accordance with the following steps.
3. Attach threaded rod to faucet body.
For 3 holes 8" centers (Series 215)
1. Place gasket and threaded rod under the base plate. Place base plate over the hole.
2. Place washer on the threaded rod and tighten with the wing nut. Faucet control should
be on the right.
3. Install washer on the base of the gooseneck spout and secure it with the shank nut on
the center hole.
4. Position faucet body with O-ring on the base plate.
5. Install supply tubes with check valves to hot and cold inlets.
Inlets are marked "H" and "C" underneath the faucet body. Install faucet outlet tube to
body. Make sure O-rings are in place.
WARNING
!
SUPPLY TUBES –HAND TIGHTEN ONLY! Over tightening , using lubricants or exposure to
corrosive materials can damage supply tube threads and cause failure, leaking, or flood
and property damage.
6. Install washer on the threaded rod and tighten with mounting nut.
7. Connect gooseneck spout to faucet body using flexible supply.
8. Connect supply tubes to water supplies.
9. With the handle in "off" position, turn on water supplies and check for leaks.
10. Remove aerator and turn faucet to hot and cold water position to flush the line thoroughly.
Replace aerator.
Troubleshooting
n
Faucet Drip
Remove cartridge and clean sealing areas on cartridge and the faucet body.
Reassemble and reset outlet temperature (refer to temperature adjustment section)
Outlet temperature is too hot or too cold
Check temperature limit stop setting (refer to temperature adjustment section)
The flow of water is insufficient or completely shutoff
Check that supply line valves are open. Remove aerator and clean.
Installation Instructions (cont.)
n
Part List
n
Index
Description
Part #
1
Handle Kit 4"
105 058
2
Handle Kit 6"
105 059
3
Cartridge Kit
105 060
4
Aerator 2.0 gpm
105 065
5
Base Plate
105 062
6
Faucet Mounting Hardware
105 063
7
Supply Tubes
105 064
T emp
TAP
™
Thermostatic Faucet with Gooseneck
Grifo termostático con cuello de cisne
Robinet thermostatique avec col de cygne
Technical Instructions
Instrucciones técnicas
Instructions techniques
IS-P-205_215
Min. Flow
to ASSE 1070
C
V
10psi
(69 kPa)
20psi
(138 kPa)
30psi
(207 kPa)
45psi
(310 kPa)
60psi
(414 kPa)
0.5 gpm
1.89 lpm
0.345 1.08 gpm
4.09 lpm
1.53 gpm
5.79 lpm
1.88 gpm
7.12 lpm
2.30 gpm
8.71 lpm
2.60 gpm
9.48 lpm
Capacity Table
* n
*Less aerator & outlet temperature of 105°F (41°C)
For two holes (Series 205)
1. Install supply tubes with
check valves to hot and
cold inlets. Inlets are
marked "H" and "C" under-
neath the faucet body.
Install faucet outlet tube
to body. Make sure
O-rings are in place.
WARNING
!
SUPPLY TUBES –HAND
TIGHTEN ONLY! Over tighten-
ing , using lubricants or exposure to corrosive materials can damage supply tube threads
and cause failure, leaking, or flood and property damage.
2. Install washer on the base of the gooseneck spout and secure it with the shank nut on the
sink.
3. Position faucet body with O-ring on the sink.
4. Install washer on the threaded rod and tighten with mounting nut.
5. Connect gooseneck spout to faucet body using flexible supply.
6. Connect supply tubes to water supplies.
7. With the handle in "off" position, turn on water supplies and check for leaks.
8. Remove aerator and turn faucet to hot and cold water position to flush the line thoroughly.
Replace aerator.
Temperature Adjustment
n
Maximum temperature setting adjustment must be set on the job to no greater than 105°F (41°C).
1. Remove handle by unscrewing set screw with allen wrench provided. Remove shroud.
2. Loosen two high temperature limit stop screws.
3. Replace handle and rotate handle clockwise to desired outlet temperature.
4. Remove handle and slide high temperature limit stop on inner bonnet ring, sliding it coun-
ter clockwise until it contacts cartridge lever.
WARNING
!
Do not exceed temperature above 105°F (41°C).
GOOSENECK SPOUT
SHANK
NUT
WASHER
WING NUT
THREADED ROD
FLEXIBLE SUPPLY
HANDLE
BASE PLATE
AERATOR
FAUCET BODY
THREADED
ROD
WASHER
MOUNTING
NUT
HOT WATER
SUPPLY
GASKET
COLD WATER
SUPPLY
5. Tighten high temperature limit stop screws.
6. Install shroud and handle.
7. Turn handle to maximum hot
position and verify temperature
setting.
Temperature Adjustment (cont.)
n
SET SCREW
INNER
BONNET
RING
HANDLE
SHROUD
CARTRIDGE
LEVER
SCREWS
HIGH
TEMPERA-
TURE
LIMIT STOP
Certified to NSF/ANSI 61
Section 9-G
Advanced
Thermal
Activation
1, 2
4
5
7
3
6
FAILURE TO COMPLY WITH PROPER INSTALLATION AND MAINTENANCE
INSTRUCTIONS COULD CONTRIBUTE TO THE VALVE FAILURE, RESULTING IN
INJURY AND/OR DEATH.
TO ENSURE THE ACCURATE AND RELIABLE OPERATION OF THIS PRODUCT, IT
IS ESSENTIAL TO:
• Properly design the system to minimize pressure and temperature variations.
• Conduct an annual maintenance program to ensure proper operation of all
critical components.
• This valve is not factory preset and can be adjusted to deliver scalding
temperatures. Check outlet temperature to ensure it does not exceed 105°F
(41°C). Make sure temperature limit stop is properly re-set to maximum
105°F (41°C) following valve maintenance or repair. Tampering with limit stop
in any way may result in scalding temperature causing serious bodily harm
and/or death.
WARNING
WARNING
!
WARNING
!
Read this Manual BEFORE using this equipment.
Failure to read and follow all safety and use information can result
in death, serious personal injury, property damage, or damage to the
equipment.
Keep this Manual for future reference.
WARNING:
This product contains chemicals known to the
State of California to cause cancer and birth defects or other
reproductive harm.
For more information: www.watts.com/prop65
ADVERTENCIA:
Este producto contiene sustancias químicas
que en el Estado de California se conocen como causantes
de cáncer y malformaciones u otros daños reproductivos.
Para más información: www
.watts.com/prop65
AVER
TISSEMENT: Ce produit contient des produits chi
-
miques reconnus par l’État de Californie comme étant can-
cérigènes et pouvant provoquer des anomalies congénitales
ou affecter la capacité de reproduction.
Pour plus d'informations: www
.watts.com/prop65
WARNING
!
Need for Periodic Inspection: Periodic inspection by a licensed contractor
is recommended. Corrosive water conditions, and/or unauthorized adjust-
ments or repair could render the valve ineffective for service intended.
Regular checking and cleaning of the valve’s internal components and
check stops helps assure maximum life and proper product function.
Frequency of cleaning and inspection depends upon local water conditions.