beautypg.com

Powers 450-e420E HydroPanel II Shower System with HydroGuard e420 Thermostatic Valve User Manual

Technical instructions, Description, Specifications

background image

Description

n

HydroPanel™ II Shower System

with HydroGuard

®

e420 Combination Valve

Technical Instructions

IS-P-450_e420

The Powers HydroPanel

II Shower System with HydroGuard

®

e420 valve combines

thermostatic and pressure balancing water control with the convenience of modular

shrouding. It provides a concealed shower system where in-wall piping does not exist

or may not be practical. The HydroGuard

®

e420 features heavy cast brass construction,

self actuated thermostatic element to quickly sense any change in hot or cold supply

water temperature or pressure and respond to maintain the user selected temperature.

In the event of cold water failure, the thermostatic element virtually shuts off the flow of

hot water. A built-in adjustable metal-to-metal temperature limit stop reduces chances

of accidental scalding due to over adjustment of handle. HydroPanel

II comes complete

with inline checkstops, stainless steel shrouding, e420 combination valve, ADA compliant

lever handle, piping, end caps and mounting hardware. Some models feature a stainless

steel soap dish. An optional hand shower comes preassembled.

Advanced Thermal Activation

Specifications

n

HydroPanel

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Brushed 18 Gauge 304 stainless steel

Piping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2" (15mm) copper tubing
Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2" (15mm) copper
Flow Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 gpm (19 lpm) +/- 0.25 gpm [0.90 lpm]
Maximum Hot Water Temperature . . . . . . . . . . 190°F (88°C)
Minimum Hot Water Temperature* . . . . . . . . . . 10°F (6°C) Above Set Point
Maximum Operating Pressure . . . . . . . . . . . . . . 125psi (862 kPa)
Showerhead . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fixed chrome plated brass

Adjustable swivel chrome plated brass

Hand Shower . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Full spray with push button
Listing/Certification (Valve only) . . . . . . . . . . . . ASSE 1016, CSA B125

*with equal pressure

FAILURE TO COMPLY WITH PROPER INSTALLATION AND

MAINTENANCE INSTRUCTIONS COULD CONTRIBUTE

TO THE VALVE FAILURE, RESULTING IN INJURY AND/OR

DEATH.
TO ENSURE THE ACCURATE AND RELIABLE OPERATION

OF THIS PRODUCT, IT IS ESSENTIAL TO:
• Properly design the system to minimize pressure and tempera-

ture variations.

• Conduct an annual maintenance program to ensure proper

operation of all critical components.

• Check outlet temperature to ensure it does not exceed

110°F (43°C). Make sure temperature limit stop is properly re-

set to maximum 110°F (43°C) following valve maintenance or

repair. Tampering with limit stop in any way may result in scald-

ing temperature causing serious bodily harm

and/or death.

Need for Periodic Inspection: Periodic inspection by a

licensed contractor is recommended. Corrosive water condi-

tions, and/or unauthorized adjustments or repair could render

the valve ineffective for service intended. Regular checking

and cleaning of the valve’s internal components and check

stops helps assure maximum life and proper product func-

tion. Frequency of cleaning and inspection depends upon

local water conditions.

WARNING

!

WARNING

!