Powers 450-e420E HydroPanel II Shower System with HydroGuard e420 Thermostatic Valve User Manual
Technical instructions, Description, Specifications
Description
n
HydroPanel™ II Shower System
with HydroGuard
®
e420 Combination Valve
Technical Instructions
IS-P-450_e420
The Powers HydroPanel
™
II Shower System with HydroGuard
®
e420 valve combines
thermostatic and pressure balancing water control with the convenience of modular
shrouding. It provides a concealed shower system where in-wall piping does not exist
or may not be practical. The HydroGuard
®
e420 features heavy cast brass construction,
self actuated thermostatic element to quickly sense any change in hot or cold supply
water temperature or pressure and respond to maintain the user selected temperature.
In the event of cold water failure, the thermostatic element virtually shuts off the flow of
hot water. A built-in adjustable metal-to-metal temperature limit stop reduces chances
of accidental scalding due to over adjustment of handle. HydroPanel
™
II comes complete
with inline checkstops, stainless steel shrouding, e420 combination valve, ADA compliant
lever handle, piping, end caps and mounting hardware. Some models feature a stainless
steel soap dish. An optional hand shower comes preassembled.
Advanced Thermal Activation
Specifications
n
HydroPanel
™
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Brushed 18 Gauge 304 stainless steel
Piping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2" (15mm) copper tubing
Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2" (15mm) copper
Flow Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 gpm (19 lpm) +/- 0.25 gpm [0.90 lpm]
Maximum Hot Water Temperature . . . . . . . . . . 190°F (88°C)
Minimum Hot Water Temperature* . . . . . . . . . . 10°F (6°C) Above Set Point
Maximum Operating Pressure . . . . . . . . . . . . . . 125psi (862 kPa)
Showerhead . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fixed chrome plated brass
Adjustable swivel chrome plated brass
Hand Shower . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Full spray with push button
Listing/Certification (Valve only) . . . . . . . . . . . . ASSE 1016, CSA B125
*with equal pressure
FAILURE TO COMPLY WITH PROPER INSTALLATION AND
MAINTENANCE INSTRUCTIONS COULD CONTRIBUTE
TO THE VALVE FAILURE, RESULTING IN INJURY AND/OR
DEATH.
TO ENSURE THE ACCURATE AND RELIABLE OPERATION
OF THIS PRODUCT, IT IS ESSENTIAL TO:
• Properly design the system to minimize pressure and tempera-
ture variations.
• Conduct an annual maintenance program to ensure proper
operation of all critical components.
• Check outlet temperature to ensure it does not exceed
110°F (43°C). Make sure temperature limit stop is properly re-
set to maximum 110°F (43°C) following valve maintenance or
repair. Tampering with limit stop in any way may result in scald-
ing temperature causing serious bodily harm
and/or death.
Need for Periodic Inspection: Periodic inspection by a
licensed contractor is recommended. Corrosive water condi-
tions, and/or unauthorized adjustments or repair could render
the valve ineffective for service intended. Regular checking
and cleaning of the valve’s internal components and check
stops helps assure maximum life and proper product func-
tion. Frequency of cleaning and inspection depends upon
local water conditions.
WARNING
!