Warranty
n
The Seller w
arrants that the equipment manufactured by it and co
vered by this
order or contract is free from defects in material and workmanship and, without
charge, equipment found to be defecti
ve in material or workmanship will be
repaired, or at Seller
’s option replaced F
.O.B. original point of shipment, if writ
ten
notice of failure is received by S
eller within one (1) year after date of shipment
(unless specifically noted elsewhere), provided said equipment has been properly
installed, operated in accordance with the Seller
’s instructions, and pro
vided such
defects are not due to abuse or decomposition by chemical or g
alvanic action.
ThiS
expreSS
w
arranTy i
S in lieu
OF and exclude
S all
OTher
warran
-
Tie
S, guaran
Tee
S,
Or repre
Sen
TaT
iO
nS
, expreSS
OF
implied. There
are
nO
implied w
arranTie
S O
F merchanTa
Bili
Ty
Or
OF F
iT
neSS
FO
r a p
ar-
Ticular purp
OSe.
The S
eller assumes no responsibility for repairs made on the
Seller
’s equipment unless done by the S
eller’s authoriz
ed personnel, or by writ
ten
authority from the Seller
. The S
eller makes no guarantee with respect to material
not manufactured by it.
Garantía
n
el V
endedor garantiza que los equipos fabricados por él y cubier
tos por esta orden
o co
ntrat
o está
n lib
res d
e def
ectos
en l
os ma
terial
es y m
ano
de ob
ra y
que l
os
equipos con materiales o mano de obra defectuosos serán reparados sin cargo
o, a opción del Vendedor
, reemplazados F .O
.B. en el punto original de envío, si
el Vendedor recibe una notificación por escrito de falla en el lapso de un (1) año
después de la fecha de en
vío (a menos que se especifique en otra parte), siempre
y cuando dichos equipos hayan sido cor
rectamente instalados y utilizados de
conformidad con las instrucciones del Vendedor
, y siempre que dichos defectos
no se
deban a
maltrato o
descomposición por
acción química
o galvánica.
e
STa
garanTÍ
a expre
Sa
reempla
Za
y
excluye cual
Quier
OT
ra garan
TÍa
,
garanTÍ
a gra
Tui
Ta
O pr
Ome
Sa
, expre
Sa
S O impl
Íci
Ta
S. n
O exi
ST
en
garanTÍ
aS
implÍci
Ta
S de
c
Omerciali
Za
ciÓ
n O
de id
Oneid
ad p
ara un
prO
pÓS
iT
O en
par
Ticular
. e
l Vendedor no asume ninguna responsabilidad
por las reparaciones hechas a los equipos del
Vendedor salv
o que se realicen por
personal autorizado por el
Vendedor o con autorización escrita del
Vendedor
. e
l
Vendedor
no otorg
a ninguna garantía
con respecto a
los materiales no
fabricados
por él.
Garantie
n
le vendeur g
arantit que l'équipement fabriqué par lui et couvert en ver
tu de
cette commande ou de ce contrat est exempt de vices de matériau et de fab
-
rication et, dans l'éventualité ou de tels vices de matériau ou de fabrication
se manifesteraient, il sera réparé sans frais ou, à la discrétion du vendeur,
remplacé franco à bord (Fa
B) de son point d'expédition d'origine (sauf si
spécifié ailleurs), pourvu que ledit équipement ait été installé cor
rectement
et utilisé conformément au
x instructions du vendeur et, pour
vu que
de tels
vices ne soient pas le résultat d’une utilisation abusive ou d'une décom
-
po
sit
ion
d
éco
ula
nt
d'u
ne
réa
cti
on
ch
im
iq
ue
ou
g
alv
an
iq
ue.
la
p
rÉ
Se
nT
e
garanTie
e
ST
expreSS
e, rempla
ce e
T exclu
T TO
uT
e a
uT
re garan
Tie
Ou
repr
ÉSen
Ta
TiO
n expre
SSe
Ou
implici
Te
. il
n
’exi
ST
e a
ucune
garanTie
Ta
ciT
e de
Quali
TÉ marchande
Ou
d
’ ad
apTa
TiO
n À
un B
uT
par
Ticulier
. le vendeur n
’assume aucune responsabilité pour des répara-
tions effectuées sur son équipement à moins qu'elles aient été ef
fectuées par
du personnel autorisé par lui ou par une autorisation écrite de lui.
le vendeur
n’of
fre aucune garantie pour les matériaux non fabriqués par lui.
T emp
TAP
™
Thermostatic Faucet
Grifo termostático
Robinet Thermostatique
Technical Instructions
Instrucciones técnicas
Instructions techniques
IS-P-105_115
USA: Phone:
1.800.669.5430
•
Fax 1.
847.229
.0526
•
www.powerscontrols.com
Canada: Phone:
1.888.208.8927
•
Fax 1
.88
8.479
.2887
•
www.powerscontrols.ca
IS-P-105_115 1333
EDP# 6512327
© 2013 Powers
USA: Phone:
1.800.669.5430
•
Fax 1.
847.229
.0526
•
www.powerscontrols.com
Canada: Phone:
1.888.208.8927
•
Fax 1
.88
8.479
.2887
•
www.powerscontrols.ca
IS-P-105_115 1333
EDP# 6512327
© 2013 Powers
USA : Phone:
1.800.669.5430
•
Fax 1.
847.229
.0526
•
www.powerscontrols.com
Canada : Phone:
1.888.208.8927
•
Fax 1
.88
8.479
.2887
•
www.powerscontrols.ca
IS-P-105_115 1333
EDP# 6512327
© 2013 Powers
Specifications
n
Connections .......................................................... 3/8" compression inlets with
checks
Maximum Operating Pressure .......................... 125psi (861 kPa)
Maximum Hot Water Temperature ................... 194°F (90°C)
Minimum Hot Water Supply Temp. ................... 5°F (3°C) Above Set-Point
Temperature Adjustment Range ....................... 60 - 120°F (15 - 49°C)
Minimum Flow ........................................................ 0.5 gpm (2.2 lpm)
Cold Water Inlet Temperature Range ............... 39 - 80°F (4 - 27°C)
Hot Water Inlet Temperature Range ................. 120 - 180°F (49 - 82°C)
Listing ..................................................................... ASSE 1070, IAPMO cUPC
Approval Standards ............................................. ASSE 1070, CSA B125.3,
NSF 61 Section 9 Annex G
Min. Flow
to ASSE 1070
C
V
10psi
(69 kPa)
20psi
(138 kPa)
30psi
(207 kPa)
45psi
(310 kPa)
60psi
(414 kPa)
0.5 gpm
1.89 lpm
0.316 1.00 gpm
3.78 lpm
1.41 gpm
5.34 lpm
1.73 gpm
6.55 lpm
2.12 gpm
8.03 lpm
2.45 gpm
9.27 lpm
*Less aerator & outlet temperature of 105°F (41°C)
Installation Instructions
n
1. Flush all piping thoroughly before installing.
2. The installation and field adjustment of TempTAP
™
faucet is the responsibility of the
installer and shall be carried out in accordance with the following steps.
3. Attach faucet threaded rod to faucet body.
For 4" centers (Series 115)
1. Place gasket and threaded rod under the base plate. Place base plate over the hole
making sure
boss
is on the back.
2. Place washers on the threaded rod and tighten with wing nuts.
3. Install sleeve on the base plate. Split on the sleeve should be on the back.
4. Position Faucet with O-ring on the base plate.
Boss
on the plate goes into the notch on
the faucet body.
5. Install supply tubes with check valves to hot and cold inlets. Inlets are marked "H" and
"C" underneath the faucet body. Make sure O-rings are in place.
WARNING
!
SUPPLY TUBES –HAND TIGHTEN ONLY! Over tightening , using lubricants or exposure to
corrosive materials can damage supply tube threads and cause failure, leaking, or flood
and property damage.
6. Install washer and tighten with mounting nut.
7. Make sure faucet is centered and facing forward before final tightening.
8. Connect inlet tubes to water supplies.
9. With the handle in "off" position, turn on water supplies and check for leaks.
10. Turn faucet to hot and cold water position to flush the line thoroughly. Install aerator.
For single hole (Series 105)
1. Install threaded rod on the faucet body.
2. Position faucet body with o-ring on the sink.
3. Install washer and tighten with mounting nut.
4. Install supply tubes with check valves to
hot and cold inlets. Inlets are marked "H"
and "C" underneath the faucet body. Make
sure O-rings are in place.
WARNING
!
SUPPLY TUBES –HAND TIGHTEN ONLY!
Over tightening , using lubricants or
exposure to corrosive materials can damage supply tube threads and cause failure, leaking, or
flood and property damage.
5. Make sure faucet is centered and facing forward before final tightening.
6. Connect inlet tubes to water supplies.
7. With the handle in "off" position, turn on water supplies and check for leaks.
8. Turn faucet to hot and cold water position to flush the line thoroughly. Install aerator.
COLD WATER
SUPPLY
THREADED
ROD
WING NUT
AERATOR
HANDLE
SLEEVE
WASHER
MOUNTING NUT
FAUCET
THREADED ROD
BASE PLATE
GASKET
HOT WATER
SUPPLY
WASHER
Temperature Adjustment
n
Maximum temperature setting adjustment must be
set on the job to no greater than 105°F (41°C).
1. Remove handle by unscrewing set screw with
allen wrench provided. Remove shroud.
2. Loosen two high temperature limit stop screws.
3. Replace handle and rotate handle clockwise to
desired outlet temperature.
4. Remove handle and slide high temperature
limit stop on inner bonnet ring, sliding it counter
clockwise until it contacts cartridge lever.
WARNING
!
Do not exceed temperature above 105°F (41°C)
5. Tighten high temperature limit stop with two screws.
6. Install shroud and handle.
7. Turn handle to maximum hot position and verify temperature setting.
SET SCREW
INNER BONNET RING
HANDLE
SHROUD
CARTRIDGE LEVER
SCREWS
HIGH
TEMPERATURE
LIMIT STOP
Troubleshooting
n
Faucet Drip
Remove cartridge and clean sealing areas on cartridge and the faucet body.
Reassemble and reset outlet temperature (refer to temperature adjustment section)
Outlet temperature is too hot or too cold
Check temperature limit stop setting (refer to temperature adjustment section)
The flow of water is insufficient or completely shutoff
Check that supply line valves are open. Remove aerator and clean.
Installation Instructions (cont.)
n
Part List
n
Index
Description
Part #
1
Handle Kit 4"
105 058
2
Handle Kit 6"
105 059
3
Cartridge Kit
105 060
4
Aerator 2.0 gpm
105 065
5
Base Plate
105 061
6
Faucet Mounting
Hardware
105 063
7
Supply Tubes
105 064
1, 2
4
5
7
6
3
Certified to NSF/ANSI 61
Section 9-G
Advanced
Thermal
Activation
WARNING
!
Read this Manual BEFORE using this equipment.
Failure to read and follow all safety and use information can result
in death, serious personal injury, property damage, or damage to the
equipment.
Keep this Manual for future reference.
WARNING:
This product contains chemicals known to the
State of California to cause cancer and birth defects or other
reproductive harm.
For more information: www.watts.com/prop65
ADVERTENCIA:
Este producto contiene sustancias químicas
que en el Estado de California se conocen como causantes
de cáncer y malformaciones u otros daños reproductivos.
Para más información: www
.watts.com/prop65
AVER
TISSEMENT: Ce produit contient des produits chi
-
miques reconnus par l’État de Californie comme étant can-
cérigènes et pouvant provoquer des anomalies congénitales
ou affecter la capacité de reproduction.
Pour plus d'informations: www
.watts.com/prop65
FAILURE TO COMPLY WITH PROPER INSTALLATION AND MAINTENANCE
INSTRUCTIONS COULD CONTRIBUTE TO THE VALVE FAILURE, RESULTING IN
INJURY AND/OR DEATH.
TO ENSURE THE ACCURATE AND RELIABLE OPERATION OF THIS PRODUCT, IT
IS ESSENTIAL TO:
• Properly design the system to minimize pressure and temperature variations.
• Conduct an annual maintenance program to ensure proper operation of all
critical components.
• This valve is not factory preset and can be adjusted to deliver scalding
temperatures. Check outlet temperature to ensure it does not exceed 105°F
(41°C). Make sure temperature limit stop is properly re-set to maximum
105°F (41°C) following valve maintenance or repair. Tampering with limit stop
in any way may result in scalding temperature causing serious bodily harm
and/or death.
WARNING
WARNING
!
Capacity Table
* n
WARNING
!
Need for Periodic Inspection: Periodic inspection by a licensed contractor
is recommended. Corrosive water conditions, and/or unauthorized adjust-
ments or repair could render the valve ineffective for service intended.
Regular checking and cleaning of the valve’s internal components and check
stops helps assure maximum life and proper product function. Frequency of