beautypg.com

Powers 105 Series TempTAP Lead Free Thermostatic Faucets User Manual

T emp tap, English instructions, Warranty

background image

ENGLISH INSTRUCTIONS

Warranty

n

The Seller w

arrants that the equipment manufactured by it and co

vered by this

order or contract is free from defects in material and workmanship and, without

charge, equipment found to be defecti

ve in material or workmanship will be

repaired, or at Seller

’s option replaced F

.O.B. original point of shipment, if writ

ten

notice of failure is received by S

eller within one (1) year after date of shipment

(unless specifically noted elsewhere), provided said equipment has been properly

installed, operated in accordance with the Seller

’s instructions, and pro

vided such

defects are not due to abuse or decomposition by chemical or g

alvanic action.

ThiS

expreSS

w

arranTy i

S in lieu

OF and exclude

S all

OTher

warran

-

Tie

S, guaran

Tee

S,

Or repre

Sen

TaT

iO

nS

, expreSS

OF

implied. There

are

nO

implied w

arranTie

S O

F merchanTa

Bili

Ty

Or

OF F

iT

neSS

FO

r a p

ar-

Ticular purp

OSe.

The S

eller assumes no responsibility for repairs made on the

Seller

’s equipment unless done by the S

eller’s authoriz

ed personnel, or by writ

ten

authority from the Seller

. The S

eller makes no guarantee with respect to material

not manufactured by it.

Garantía

n

el V

endedor garantiza que los equipos fabricados por él y cubier

tos por esta orden

o co

ntrat

o está

n lib

res d

e def

ectos

en l

os ma

terial

es y m

ano

de ob

ra y

que l

os

equipos con materiales o mano de obra defectuosos serán reparados sin cargo

o, a opción del Vendedor

, reemplazados F .O

.B. en el punto original de envío, si

el Vendedor recibe una notificación por escrito de falla en el lapso de un (1) año

después de la fecha de en

vío (a menos que se especifique en otra parte), siempre

y cuando dichos equipos hayan sido cor

rectamente instalados y utilizados de

conformidad con las instrucciones del Vendedor

, y siempre que dichos defectos

no se

deban a

maltrato o

descomposición por

acción química

o galvánica.

e

STa

garanTÍ

a expre

Sa

reempla

Za

y

excluye cual

Quier

OT

ra garan

TÍa

,

garanTÍ

a gra

Tui

Ta

O pr

Ome

Sa

, expre

Sa

S O impl

Íci

Ta

S. n

O exi

ST

en

garanTÍ

aS

implÍci

Ta

S de

c

Omerciali

Za

ciÓ

n O

de id

Oneid

ad p

ara un

prO

pÓS

iT

O en

par

Ticular

. e

l Vendedor no asume ninguna responsabilidad

por las reparaciones hechas a los equipos del

Vendedor salv

o que se realicen por

personal autorizado por el

Vendedor o con autorización escrita del

Vendedor

. e

l

Vendedor

no otorg

a ninguna garantía

con respecto a

los materiales no

fabricados

por él.

Garantie

n

le vendeur g

arantit que l'équipement fabriqué par lui et couvert en ver

tu de

cette commande ou de ce contrat est exempt de vices de matériau et de fab

-

rication et, dans l'éventualité ou de tels vices de matériau ou de fabrication

se manifesteraient, il sera réparé sans frais ou, à la discrétion du vendeur,

remplacé franco à bord (Fa

B) de son point d'expédition d'origine (sauf si

spécifié ailleurs), pourvu que ledit équipement ait été installé cor

rectement

et utilisé conformément au

x instructions du vendeur et, pour

vu que

de tels

vices ne soient pas le résultat d’une utilisation abusive ou d'une décom

-

po

sit

ion

d

éco

ula

nt

d'u

ne

réa

cti

on

ch

im

iq

ue

ou

g

alv

an

iq

ue.

la

p

Se

nT

e

garanTie

e

ST

expreSS

e, rempla

ce e

T exclu

T TO

uT

e a

uT

re garan

Tie

Ou

repr

ÉSen

Ta

TiO

n expre

SSe

Ou

implici

Te

. il

n

’exi

ST

e a

ucune

garanTie

Ta

ciT

e de

Quali

TÉ marchande

Ou

d

’ ad

apTa

TiO

n À

un B

uT

par

Ticulier

. le vendeur n

’assume aucune responsabilité pour des répara-

tions effectuées sur son équipement à moins qu'elles aient été ef

fectuées par

du personnel autorisé par lui ou par une autorisation écrite de lui.

le vendeur

n’of

fre aucune garantie pour les matériaux non fabriqués par lui.

T emp

TAP

Thermostatic Faucet

Grifo termostático

Robinet Thermostatique

Technical Instructions

Instrucciones técnicas

Instructions techniques

IS-P-105_115

USA:  Phone:

 1.800.669.5430

 • 

Fax 1.

847.229

.0526

 • 

www.powerscontrols.com

Canada:  Phone:

 1.888.208.8927

 • 

Fax 1

.88

8.479

.2887

 • 

www.powerscontrols.ca

IS-P-105_115 1333

EDP# 6512327

© 2013 Powers

USA:  Phone:

 1.800.669.5430

 • 

Fax 1.

847.229

.0526

 • 

www.powerscontrols.com

Canada:  Phone:

 1.888.208.8927

 • 

Fax 1

.88

8.479

.2887

 • 

www.powerscontrols.ca

IS-P-105_115 1333

EDP# 6512327

© 2013 Powers

USA :  Phone:

 1.800.669.5430

 • 

Fax 1.

847.229

.0526

 • 

www.powerscontrols.com

Canada :  Phone:

 1.888.208.8927

 • 

Fax 1

.88

8.479

.2887

 • 

www.powerscontrols.ca

IS-P-105_115 1333

EDP# 6512327

© 2013 Powers

Specifications

n

Connections .......................................................... 3/8" compression inlets with

checks

Maximum Operating Pressure .......................... 125psi (861 kPa)

Maximum Hot Water Temperature ................... 194°F (90°C)

Minimum Hot Water Supply Temp. ................... 5°F (3°C) Above Set-Point

Temperature Adjustment Range ....................... 60 - 120°F (15 - 49°C)

Minimum Flow ........................................................ 0.5 gpm (2.2 lpm)

Cold Water Inlet Temperature Range ............... 39 - 80°F (4 - 27°C)

Hot Water Inlet Temperature Range ................. 120 - 180°F (49 - 82°C)

Listing ..................................................................... ASSE 1070, IAPMO cUPC

Approval Standards ............................................. ASSE 1070, CSA B125.3,

NSF 61 Section 9 Annex G

Min. Flow

to ASSE 1070

C

V

10psi

(69 kPa)

20psi

(138 kPa)

30psi

(207 kPa)

45psi

(310 kPa)

60psi

(414 kPa)

0.5 gpm

1.89 lpm

0.316 1.00 gpm

3.78 lpm

1.41 gpm

5.34 lpm

1.73 gpm

6.55 lpm

2.12 gpm

8.03 lpm

2.45 gpm

9.27 lpm

*Less aerator & outlet temperature of 105°F (41°C)

Installation Instructions

n

1. Flush all piping thoroughly before installing.
2. The installation and field adjustment of TempTAP

faucet is the responsibility of the

installer and shall be carried out in accordance with the following steps.

3. Attach faucet threaded rod to faucet body.

For 4" centers (Series 115)

1. Place gasket and threaded rod under the base plate. Place base plate over the hole

making sure

boss

is on the back.

2. Place washers on the threaded rod and tighten with wing nuts.
3. Install sleeve on the base plate. Split on the sleeve should be on the back.

4. Position Faucet with O-ring on the base plate.

Boss

on the plate goes into the notch on

the faucet body.

5. Install supply tubes with check valves to hot and cold inlets. Inlets are marked "H" and

"C" underneath the faucet body. Make sure O-rings are in place.

WARNING

!

SUPPLY TUBES –HAND TIGHTEN ONLY! Over tightening , using lubricants or exposure to

corrosive materials can damage supply tube threads and cause failure, leaking, or flood

and property damage.

6. Install washer and tighten with mounting nut.

7. Make sure faucet is centered and facing forward before final tightening.

8. Connect inlet tubes to water supplies.

9. With the handle in "off" position, turn on water supplies and check for leaks.

10. Turn faucet to hot and cold water position to flush the line thoroughly. Install aerator.

For single hole (Series 105)
1. Install threaded rod on the faucet body.
2. Position faucet body with o-ring on the sink.
3. Install washer and tighten with mounting nut.
4. Install supply tubes with check valves to

hot and cold inlets. Inlets are marked "H"

and "C" underneath the faucet body. Make

sure O-rings are in place.

WARNING

!

SUPPLY TUBES –HAND TIGHTEN ONLY!

Over tightening , using lubricants or

exposure to corrosive materials can damage supply tube threads and cause failure, leaking, or

flood and property damage.
5. Make sure faucet is centered and facing forward before final tightening.
6. Connect inlet tubes to water supplies.
7. With the handle in "off" position, turn on water supplies and check for leaks.
8. Turn faucet to hot and cold water position to flush the line thoroughly. Install aerator.

COLD WATER

SUPPLY

THREADED

ROD

WING NUT

AERATOR

HANDLE

SLEEVE

WASHER

MOUNTING NUT

FAUCET

THREADED ROD

BASE PLATE

GASKET

HOT WATER

SUPPLY

WASHER

Temperature Adjustment

n

Maximum temperature setting adjustment must be

set on the job to no greater than 105°F (41°C).
1. Remove handle by unscrewing set screw with

allen wrench provided. Remove shroud.

2. Loosen two high temperature limit stop screws.
3. Replace handle and rotate handle clockwise to

desired outlet temperature.

4. Remove handle and slide high temperature

limit stop on inner bonnet ring, sliding it counter

clockwise until it contacts cartridge lever.

WARNING

!

Do not exceed temperature above 105°F (41°C)

5. Tighten high temperature limit stop with two screws.
6. Install shroud and handle.
7. Turn handle to maximum hot position and verify temperature setting.

SET SCREW

INNER BONNET RING

HANDLE

SHROUD

CARTRIDGE LEVER

SCREWS

HIGH

TEMPERATURE

LIMIT STOP

Troubleshooting

n

Faucet Drip
Remove cartridge and clean sealing areas on cartridge and the faucet body.

Reassemble and reset outlet temperature (refer to temperature adjustment section)

Outlet temperature is too hot or too cold
Check temperature limit stop setting (refer to temperature adjustment section)

The flow of water is insufficient or completely shutoff
Check that supply line valves are open. Remove aerator and clean.

Installation Instructions (cont.)

n

Part List

n

Index

Description

Part #

1

Handle Kit 4"

105 058

2

Handle Kit 6"

105 059

3

Cartridge Kit

105 060

4

Aerator 2.0 gpm

105 065

5

Base Plate

105 061

6

Faucet Mounting

Hardware

105 063

7

Supply Tubes

105 064

1, 2

4

5

7

6

3

Certified to NSF/ANSI 61

Section 9-G

Advanced

Thermal

Activation

WARNING

!

Read this Manual BEFORE using this equipment.

Failure to read and follow all safety and use information can result

in death, serious personal injury, property damage, or damage to the

equipment.

Keep this Manual for future reference.

WARNING:

This product contains chemicals known to the

State of California to cause cancer and birth defects or other

reproductive harm.

For more information: www.watts.com/prop65

ADVERTENCIA:

Este producto contiene sustancias químicas

que en el Estado de California se conocen como causantes

de cáncer y malformaciones u otros daños reproductivos.

Para más información: www

.watts.com/prop65

AVER

TISSEMENT: Ce produit contient des produits chi

-

miques reconnus par l’État de Californie comme étant can-

cérigènes et pouvant provoquer des anomalies congénitales

ou affecter la capacité de reproduction.

Pour plus d'informations: www

.watts.com/prop65

FAILURE TO COMPLY WITH PROPER INSTALLATION AND MAINTENANCE

INSTRUCTIONS COULD CONTRIBUTE TO THE VALVE FAILURE, RESULTING IN

INJURY AND/OR DEATH.

TO ENSURE THE ACCURATE AND RELIABLE OPERATION OF THIS PRODUCT, IT

IS ESSENTIAL TO:

• Properly design the system to minimize pressure and temperature variations.

• Conduct an annual maintenance program to ensure proper operation of all

critical components.

• This valve is not factory preset and can be adjusted to deliver scalding

temperatures. Check outlet temperature to ensure it does not exceed 105°F

(41°C). Make sure temperature limit stop is properly re-set to maximum

105°F (41°C) following valve maintenance or repair. Tampering with limit stop

in any way may result in scalding temperature causing serious bodily harm

and/or death.

WARNING

WARNING

!

Capacity Table

* n

WARNING

!

Need for Periodic Inspection: Periodic inspection by a licensed contractor

is recommended. Corrosive water conditions, and/or unauthorized adjust-

ments or repair could render the valve ineffective for service intended.

Regular checking and cleaning of the valve’s internal components and check

stops helps assure maximum life and proper product function. Frequency of

cleaning and inspection depends upon local water conditions.

This manual is related to the following products: