beautypg.com

Installation, Figure 4 – Powers 450-410 HydroPanel II Shower System User Manual

Page 2

background image

TI450-410

Page 2

Before installation of any Hydropanel II unit, rotate the stem (or
handle) of the valve to its full clockwise position (OFF).

POSITION THE HYDROPANEL II UNIT

(See Figures 1 and 2) Determine the horizontal position of the unit
according to shower room layout, and mark the centerlines. For
multiple shower applications, the recommended minimum dis-
tance between the centerline of two units is 36 inches [914mm].

1. Determine the floor-to-showerhead height for the unit.

Recommended heights are listed below:

Men - 77” [1956mm]

Youth - 66” [1676mm]

Women - 70” [1778mm]

Youth - 60” [1524mm]

2. The preassembled copper tubing for supply water inlets are

6-5/8” [168mm] from the top of the shroud, and 2-11/16”
[68mm] left and right of the centerline. Adjust supply piping
accordingly.

Install the Piping Assembly

The piping and Hydropanel II shrouding must be separated
before mounting to wall. The valve trim and cover plate are in a
separate plastic bag in the Hydropanel II shipping carton. For
#450-0414 and #450-0415 Hydropanel II units, the handshower,
hose and showerhead base come preassembled to the shroud-
ing. Refer to Figure 4.

3. Detach the piping from the shrouding, by removing screw A

above the showerhead. Slide piping out of the shrouding;
the shower head remains attached to the shroud.

4. For mounting the piping assembly upper bracket B, use

bracket as a template and drill two small holes in the wall at
showerhead height.

5. For mounting the piping assembly lower bracket C, drill two

small holes in the wall that are 18-3/4” [476mm] below the
upper bracket and 11/16” [17mm] left and right of centerline.

6. Install any mounting anchors as detailed by the individual

room specifications.

7. Secure upper piping bracket B with mounting screws (not

included).

8. Secure lower piping bracket C with mounting screws (not

included).

9. Connect the supply lines to the piping assembly.

Attach the Shrouding

Do Not remove the entire chrome plated end cap from the
shrouding; it functions as an end cap and gasket for shroud
extension. Part of the end cap can be broken out to provide verti-
cal and horizontal piping clearance.

10.To remove scored section, hit it sharply with a hammer.

11.To connect the showerhead on the shroud to the water out-

let pipe, slide the showerhead nipple on the inside of the
shroud into the piping assembly. The End Cap will slide over
the supply piping. Secure the shrouding with the screw at A.

Test the System

Before final assembly, test the Hydropanel II system.

12. Fit the handle onto the valve stem and turn clockwise to the

shut off position.

13.Turn on water supply, and then rotate the valve handle coun-

terclockwise. Water should come through the showerhead.

14.Now turn handle fully counterclockwise and measure the

temperature of the outlet water. Wait until the temperature
stabilizes for an accurate reading.

15.Turn off valve (fully clockwise) and check all connections

(showerhead, pipe connections, valve bonnet) for leaks.

INSTALLATION

L

H

C

POWERS

7-1/2"

[191]

7-3/32"

[180]

11/16"

[18]

2-11/16"

[68]

C for Hydropanel unit

6-5/8"

[168]

H

C

POWERS

18"

[457]

10-5/8"

[270]

1-3/8"

[35]

2-1/2"

[64]

4-3/4"

[121]

FLOOR LINE

6-1/2"

[165]

7/16"

[11]

30"

[762]

1/2"
Copper Inlets

6"

[154]

21-1/4"

[540]

1-1/4"

[32]

For Suggested

Showerhead

Height see

General

Installation

2-3/4"

[70]

Figure 1: Front dimensions,
Hydropanel II Model 450-0412.

Figure 2: Side dimensions,
Hydropanel II
Model 450-0412.

Figure 3: Front dimensions,
Hydropanel II
Model 450-0414.

A

C

B

D'

D

END CAP

HOT

COLD

18-3/4"

[476]

1-3/4"

[44]

11/16"

[17]

2-11/6"

[68]

2-1/4"

[57]

Figure 4.