beautypg.com

Warranty, Maintenance and troubleshooting, continued, Parts list – Powers 450 Infrared ESP HydroPanel II Infrared Sensor System User Manual

Page 4

background image

IS-P-450S Page 4

1

2

3

4

5

6

No.

Description

Part No.

1

Sensor Assembly for Infrared Shower

450 555

2

Solenoid Assembly (brass)

444 175

3

Installation Kit, Modular Junction Box

450 559

4

Box Transformer

444 119

5

Swivel Showerhead

141 815

6

Fixed Showerhead

141 816

Not Shown

Maintenance/Repair Kit, Solenoid (brass)

444 183

USA:  Phone: 1.800.669.5430 • Fax 1.847. 229.0526 • www.powerscontrols.com

Canada:  Phone: 1.888.208.8927 • Fax 1.888.479.2887 • www.powerscontrols.ca

IS-P-450S 1003

EDP# 6512242

© 2010 Powers

Warranty

n

The Seller warrants that the equipment manufactured by it and covered by this order or contract is free from defects in material and workmanship and,

without charge, equipment found to be defective in material or workmanship will be repaired, or at Seller’s option replaced F.O.B. original point of shipment,

if written notice of failure is received by Seller within one (1) year after date of shipment (unless specifically noted elsewhere), provided said equipment has

been properly installed, operated in accordance with the Seller’s instructions, and provided such defects are not due to abuse or decomposition by chemical

or galvanic action. ThiS expreSS warranTy iS in lieu OF and excludeS all OTher warranTieS, guaranTeeS, Or repreSenTaTiOnS, expreSS

OF implied. There are nO implied warranTieS OF merchanTaBiliTy Or OF FiTneSS FOr a parTicular purpOSe. The Seller assumes no responsi-

bility for repairs made on the Seller’s equipment unless done by the Seller’s authorized personnel, or by written authority from the Seller. The Seller makes no

guarantee with respect to material not manufactured by it.

A Watts Water Technologies Company

c. Check that solenoid wires are securely attached.
d. The maximum run-time may have elapsed. The sensor will

remain lit even though the solenoid has closed. For a longer

shower-run time, reset the run-time potentiometer.

3. If water runs continuously, regardless of sensor activity:
a. FIRST unplug solenoid from the modular junction box.
b. If water continues to run...

• Debris and/or lime build-up may be preventing solenoid

from closing. Dismantle, clean and flush the solenoid valve

c. If water stops after disconnecting power...
• The problem is electronic. Check that power wires are

connected properly in the Modular Junction Box, and

check all electrical connections.

Maintenance and Troubleshooting, Continued

n

Parts List

n