IS-P-450S Page 4
1
2
3
4
5
6
No.
Description
Part No.
1
Sensor Assembly for Infrared Shower
450 555
2
Solenoid Assembly (brass)
444 175
3
Installation Kit, Modular Junction Box
450 559
4
Box Transformer
444 119
5
Swivel Showerhead
141 815
6
Fixed Showerhead
141 816
Not Shown
Maintenance/Repair Kit, Solenoid (brass)
444 183
USA: Phone: 1.800.669.5430 • Fax 1.847. 229.0526 • www.powerscontrols.com
Canada: Phone: 1.888.208.8927 • Fax 1.888.479.2887 • www.powerscontrols.ca
IS-P-450S 1003
EDP# 6512242
© 2010 Powers
Warranty
n
The Seller warrants that the equipment manufactured by it and covered by this order or contract is free from defects in material and workmanship and,
without charge, equipment found to be defective in material or workmanship will be repaired, or at Seller’s option replaced F.O.B. original point of shipment,
if written notice of failure is received by Seller within one (1) year after date of shipment (unless specifically noted elsewhere), provided said equipment has
been properly installed, operated in accordance with the Seller’s instructions, and provided such defects are not due to abuse or decomposition by chemical
or galvanic action. ThiS expreSS warranTy iS in lieu OF and excludeS all OTher warranTieS, guaranTeeS, Or repreSenTaTiOnS, expreSS
OF implied. There are nO implied warranTieS OF merchanTaBiliTy Or OF FiTneSS FOr a parTicular purpOSe. The Seller assumes no responsi-
bility for repairs made on the Seller’s equipment unless done by the Seller’s authorized personnel, or by written authority from the Seller. The Seller makes no
guarantee with respect to material not manufactured by it.
A Watts Water Technologies Company
c. Check that solenoid wires are securely attached.
d. The maximum run-time may have elapsed. The sensor will
remain lit even though the solenoid has closed. For a longer
shower-run time, reset the run-time potentiometer.
3. If water runs continuously, regardless of sensor activity:
a. FIRST unplug solenoid from the modular junction box.
b. If water continues to run...
• Debris and/or lime build-up may be preventing solenoid
from closing. Dismantle, clean and flush the solenoid valve
c. If water stops after disconnecting power...
• The problem is electronic. Check that power wires are
connected properly in the Modular Junction Box, and
check all electrical connections.