beautypg.com

User displays, B. setting time of day, A. general operation – Watts W100T Twin Alternating Series User Manual

Page 9

background image

W100T Twin Alternating Series Softeners

9

User 1

Typical user display. If volume is selected in Configuration Settings

Step 4CS, shows volume remaining to regeneration. If volume is not

selected in Configuration Settings Step 4CS, this screen will not be

shown. If a meter is not used this display will not change.

User 2

Displays number of days to next regeneration.

User 3

Displays flow rate in gallons per minute. If a meter is not used this

display will be shown but 0 will be displayed. If 1.0 is selected in

Step 2CS an “A” in front of the flow rate indicates that the tank with

the control valve on it is in service. If “b” is displayed the tank with the

in/out head is in service.
This screen will not be shown if 7 day or 28 day is selected in

Configuration Settings Step 4CS.

User 4

Displays total flow in gallons since last reset. If a meter is not used this

display will be shown but 0 will be displayed. This screen will not be

shown if 7 day or 28 day is selected in Configuration Settings Step

4CS.

PRESS

▼ FOR 3 SECONDS TO RESET TO 0.

User 5

Shows current time.

B. Setting Time of Day

• Push NEXT until time of day screen is displayed. Press and

hold

▲or ▼ until the SET indicator is displayed, and the hour

flashes. Press

▲or ▼until the correct hour is displayed.

• Then press NEXT. The minutes will flash. Press

▲or ▼until

the correct minute is displayed.

• Press NEXT to return to the Display Screens. Time of day

should only need to be set after power outages lasting more

than 8 hours, if the battery has been depleted and a power

outage occurs, or when daylight saving time begins or ends.

If a power outage lasting more than 8 hours occurs, the time

of day will flash on and off which indicates the time of day

should be reset. If a power outage lasts less than 8 hours

and the time of day flashes on and off, the time of day should

be reset and the battery replaced.

User Displays

A. General Operation

When the system is operating, one of five displays may be shown. Pressing

NEXT will alternate between the displays shown below.