10 W100T Twin Alternating Series Softeners

Configuration Settings

Step 1CS

Press

and

▼ simultaneously for 5 seconds and release. If screen in Step 2CS does not appear, the

lock on the valve is activated. To unlock press

▼, NEXT, REGEN, ▲ in sequence, then press ▲

and

simultaneously for 5 seconds and release.

Step 1CS

Step 2CS

Step 3CS

Step 4CS

Step 5CS

EXIT TO
DISPLAY
SCREENS

Step 4CS

Press

▲or ▼ to select one of the following:

¹ When using the CWS200 control valve, the circuit board software must have meter selection choices of 2.0 and 2.0L. The CWS200 valve must be set for the 2.0 meter

selection during programming. If the software version does not have both the 2.0 and 2.0L selections, consult your equipment supplier for a replacement circuit board. When

using the CWS200 valve with older version software that does not have both 2.0 and 2.0L selection choices, the valve must be set to 2.0 during programming. If a CWS200

valve is being used with newer version software that has both 2.0 and 2.0L selection choices, the valve must be set to 2.0L during programming.

2

For software rev 519.3 or higher.

Step 1CS

Step 2CS

Step 3CS

Step 4CS

Step 5CS

EXIT TO
DISPLAY
SCREENS

Step 4CS

Step 5CS

Press

▲or ▼ to select to regenerate immediately on 0 or at delayed time. Immediately on 0 can only be

selected if Volume (gallons) was selected in step 4CS and a meter must be installed. Delay is the only

option for the other Step 4CS selections. Press NEXT to go to Step 6CS. Press REGEN to return to

previous step.

Step 1CS

Step 2CS

Step 3CS

Step 4CS

Step 5CS

EXIT TO
DISPLAY
SCREENS

Step 5CS

Step 3CS

When 2.0L or 2.0 are selected, an additional screen will appear. It is used to select which size flow meter is

to be used with the valve, 1.5 or 2.0.
Press NEXT to go to Step 4CS. Press REGEN to return to previous step.

Step 3CS

• If 28/Volume (gallons) is selected the regeneration will occur on the day (1 through 28) selected in

Installer Display Settings. If a meter is not used the total flow and flow rate user displays and the volume

display in Diagnostics will be shown as 0.

• If 7/Volume (gallons) is selected the regeneration will occur on the selected day(s) of the week (see

instructions contained in Installer Display Settings). If a meter is not used the total flow and flow rate user

displays and the volume display in Diagnostics will be shown as 0.

• If 7 is selected the regeneration will occur on the selected day(s) of the week (see instructions contained

in Installer Display Settings). The total flow and flow rate user displays and the volume display in

Diagnostics will not be shown even if a meter is used.

Press NEXT to go to Step 5CS. Press REGEN to return to previous step.

• If 28 is selected the regeneration will occur on the day (1 through 28) selected in Installer Display

Settings. The total flow and flow rate user displays and the volume display in Diagnostics will not be

shown even if a meter is used.

• If Volume (gallons) is selected the regeneration will occur after the specific volume has been used or on

the day override (if selected) whichever comes first.

Step 2CS

Choose 1.0 for 1”, 1.25 for 1.25”, 1.5 for 1.5”, 2.0L for 2L, 2.0 for 2” valve¹, 1.0 for 1” twin valve

2

.

Press NEXT to go to Step 3CS. Press REGEN to exit Configuration Settings.

When using the CWS200 valve, if “2L” is set instead on “2.0” for valve type, when the valve is in

regeneration and the piston drives to the “Draw” cycle the piston will stall and generate a 1002 error code.

Clear error code by pressing NEXT and REGEN simultaneously until the valve resets, then re-program to

proper valve type setting.

NOTICE