Installer display settings – Watts W100T Twin Alternating Series User Manual
Page 15

W100T Twin Alternating Series Softeners
15
Step 2I
Volumetric capacity in gallons to regeneration. Press NEXT to go
to Step 3I. Press REGEN to exit Installer Display.
Step 3I
Adjust day override from 1 - 28 or OFF. Press NEXT to go to
Step 4I. Press REGEN to return to previous step.
Step 4I
Use
▲or ▼ to set the regen hour.
Press NEXT to go to Step 5I. Press REGEN to return to the
previous step.
Installer Display Settings
Step 1I
To enter Installer Display press NEXT and
▲ simultaneously for
5 seconds and release.
B. 28 Day or 28/Volume (Gallons) selected in Configuration Settings Step 4CS
Step 1I
To enter Installer Display
press NEXT and
▲ simultaneously for
five seconds and release.
Step 2I
Adjust days from 1 - 28. Press NEXT to go to Step 3I. Press
REGEN to exit Installer Display.
Step 3I
Use
▲or ▼ to set time of the regen hour. Press NEXT to go to
Step 4I. Press REGEN to return to previous step.
Step 4I
Use
▲or ▼ to set the regen minutes. Press NEXT to exit
Installer Display. Press REGEN to return to previous step.
One of three sets of displays will be shown depending on what was selected in Configuration Settings Step 4CS.
A. Volume (Gallons) selected in Configuration Settings Step 4CS
Step 5I
Use
▲or ▼ to set the regen minutes. Press NEXT to exit
Installer Display. Press REGEN to return to previous step.
Step 2I
Step 3I
Step 1I
Step 4I
Step 5I
EXIT TO
DISPLAY
SCREENS
Step 2I
Step 3I
Step 1I
Step 4I
EXIT TO
DISPLAY
SCREENS