14 W100T Twin Alternating Series Softeners

Setting Regeneration Cycle Times

Step 1CT

Press NEXT and

▼ simultaneously for 5 seconds and release. If screen in Step

2CT does not appear, the lock on the valve is activated. To unlock press

▼, NEXT,

REGEN,

▲ in sequence, then press NEXT and ▼ simultaneously for 5 seconds and

release.

Step 3CT

Adjust the length of the backwash from 1-95 minutes using

▲or ▼.

Press NEXT to go to Step 4CT. Press REGEN to return to previous step.

Step 4CT

Adjust the length of the regenerant draw from 1-180 minutes using

▲or ▼.

Press NEXT to go to Step 5CT. Press REGEN to return to previous step.

Step 5CT

Adjust the length of the second backwash from 1-95 minutes using

▲or ▼.

Press NEXT to go to Step 6CT. Press REGEN to return to previous step.

Step 6CT

Adjust the length of rinse from 1-95 minutes using

▲or ▼.

Press NEXT to go to Step 7CT. Press REGEN to return to previous step.

Step 7CT

Adjust the length of fill from 0.1-99.0 minutes or OFF. CWS200 valves are shipped

from the factory with a refill flow control of 2.2 gpm (8.3 lpm). All other control valves

are shipped from the factory with a refill flow control of 0.5 gpm (1.9 lpm).

Press NEXT to exit Regeneration Cycle Times. Press REGEN to return to previous

step.

Step 2CT

Select between SOFTENING or FILTERING.
When set to FLTr, only Steps 3CT and 6CT are available.
Press NEXT to go to Step 3CT. Press REGEN to exit Regeneration Cycle Times.

Step 1CT

Step 3

CT

Step 4

CT

Step 5

CT

EXIT TO

DISPLAY

SCREENS

Step 7

CT

Step 6

CT

Step 1CT

Step 3

CT

Step 4

CT

Step 5

CT

EXIT TO

DISPLAY

SCREENS

Step 7

CT

Step 6

CT

Flow

Rate

AM

Time

Set

Volume

X1000

Regen

Backwash

Brine

Rinse

Fill

PM Days To

Regen

Step 2CT

Step 1CS

Step 2CS

Step 3CS

Step 4CS

Step 5CS

EXIT TO
DISPLAY
SCREENS