beautypg.com

700 series advanced programming – Watts Autotrol 263 / 268 (Logix Series) User Manual

Page 42

background image

42

PROGRAMMING THE 700 FOR 5-CYCLE FILTER APPLICA-

TIONS

700 Series Advanced Programming

The 700 Series controllers are designed to operate by only setting the time
of day and the day of the week. The remaining settings have been set at
the factory. These default settings will work for most applications.
To change a setting:

This level of programming is accessible by pressing the SET button. The
UP and DOWN arrows will step through the settings:

Time of day
Day of week
Time of regeneration
Number of days between regeneration (99 day timer)
Day of week regeneration (displays only when number of days
between regeneration equals zero) (7 day timer)
Amount of regenerant used per regeneration or filter backwash time
System capacity (view only)

Action

Key

Duration

Display

Enter basic
programming

SET

Press and
Release

Will show day of week

Move to desired
display

UP or DOWN
arrows

Press and
Release

Will increment through
the displays

Enable setting to be
changed

SET

Press and
Release

Display will flash

Change setting

UP or DOWN
arrows

Press and
Release

Value changes and
continues to flash

Save setting

SET

Press and
Release

Display stops flashing

Return to operation

REGEN

Press and
Release

Normal operation display

View history values

SET and DOWN

Press and
Hold for 5
seconds

HO will be displayed

For Regeneration

SET

UP arrow

DOWN
arrow