Supply Voltage and Current

Model AT-AM-2A: 115V ac ± 15% at 100 mA

Model AT-BM-2A: 230V ac ± 15% at 50 mA

Model AT-FM-2A: 24V ac/dc ± 15% at 250 mA

Supply Protection Circuitry

Protected against transient voltages and reverse polarity (dc hookup is without regard to polarity)

Output Configuration

(including Auxiliary N.C.

output 51/52)

Outputs (K1 and K2): two redundant (total of four) safety relay (forced-guided) contacts

Contact ratings:

Maximum voltage: 250V ac or 250V dc

Maximum current: 4A ac or dc (resistive load)

Maximum power: 1000 VA, 200 watts

Mechanical life: 10,000,000 operations

Electrical life: 100,000 cycles (typically @ 1.0 kVA switching power)

NOTE: Transient suppression is recommended when switching inductive loads. Install suppressors across

load. Never install suppressors across output contacts (see Warning on page 8).

Auxiliary Monitor Output (K3): One non-safety relay contact

Maximum switching voltage: 125V ac or dc

Maximum switching current: 500 mA (resistive load)

Contact Fuse Protection

6.3 A quick or 4 A slow

Output Response Time

25 milliseconds maximum

Input Requirements

Outputs from actuating devices must each be capable of switching 40 to 100 mA @ 12 to 18V dc.

Simultaneity Monitoring

Period

300 milliseconds (typical)

< 500 milliseconds under single-fault conditions

Status Indicators

3 green LED indicators (see Figure 1):

Power ON

K1 energized

K2 energized

1 red LED indicator:

Fault

Housing

Polycarbonate. Rated NEMA 1 (IEC IP20)

Mounting

Mounts to standard 35 mm DIN rail track. Safety Module must be installed inside an enclosure rated

NEMA 3 (IEC IP54), or better.

Vibration Resistance

10 to 55Hz @ 0.35 mm displacement per IEC 68-2-6

Operating Conditions

Temperature: 0° to +50°C (+32° to 122°F)

Maximum Relative Humidity: 90% @ +50°C (non-condensing)

Heat Dissipation Considerations: See page 4.

Dimensions

See Figure 6.

Safety Category

1 and 3 per ISO 13849-1; Type IIIA/B per ISO 13851 (EN574)

(Dependent on hookup and installation of the hand controls)

Certifications

Specifications