Pollution Degree
2
Output Configuration
Each normally open output channel is a series connection of contacts from two forced-guided (mechanically linked) relays,
K1-K2.
Contacts: AgNi, 5 µm gold-plated
Low Current Rating: The 5 µm gold-plated contacts allow the switching of low current/low voltage. In these low-power
applications, multiple contacts can also be switched in series (e.g., “dry switching”). To preserve the gold plating on the
contacts, do not exceed the following max. values at any time:
Min. voltage: 1V ac/dc
Max. voltage: 60V
Min. current: 5 mA ac/dc
Max. current: 300 mA
Min. power: 5 mW (5 mVA)
Max. power: 7 W (7 VA)
High Current Rating: If higher loads must be switched through one or more of the contacts, the minimum and maximum
values of the contact(s) changes to:
Minimum:
Maximum:
Voltage:
15V ac/dc
250V ac / 24V dc, 6 A resistive
Current:
30 mA ac/dc
——
Power:
0.45 W (0.45 VA)
——
Voltage:
15V ac/dc
250V ac / 24V dc, 6 A resistive
Current:
30 mA ac/dc
IEC 60947-5-1; AC15: 230V ac, 3 A;
DC-13: 24V dc, 2 A
Power:
0.45 W (0.45 VA)
——
Mechanical life: 20,000,000 operations
Electrical life (switching cycles of the output contacts, resistive load): 150,000 cycles @ 900 VA; 1,000,000 cycles @
250 VA; 2,000,000 cycles @ 150 VA; 5,000,000 cycles @ 100 VA
Output Response Time
35 milliseconds maximum
Input Requirements
Outputs from actuating devices must each be capable of switching 25 mA @ 24V dc (nominal).
Simultaneity Monitoring Period
≤ 500 milliseconds
Status Indicators
4 green LED indicators: Power ON, Input 1 energized, Input 2 energized, Output
1 red LED indicator: Fault
Construction
Polycarbonate housing. Rated IEC IP20
Mounting
Mounts to standard 35 mm DIN rail track. Safety Module must be installed inside an enclosure rated NEMA 3 (IEC IP54), or
better.
Vibration Resistance
10 to 55 Hz @ 0.35 mm displacement per IEC 60068-2-6
Operating Conditions
Temperature: 0° to +50°C (+32° to 122°F) See "Heat Dissipation Considerations."
Maximum Relative Humidity: 90% @ +50°C (non-condensing)
Dimensions
See following figure.
AT-FM-10K Two-Hand Control Module
12
www.bannerengineering.com - tel: 763-544-3164
P/N 64137 Rev. G