Figure 9, Mounting aspiration filter, Figure 10 – Metrohm 882 Compact IC plus – Anion User Manual
Page 35: Install tubing weighting and aspiration filter, Tubing (8-1), 4) and screw tight
■■■■■■■■■■■■■■■■■■■■■■
3 Installation
882 Compact IC plus – Anion
■■■■■■■■
25
1
Eluent aspiration tubing (6.1834.080)
2
Tubing nipple
From accessories set (6.1602.160).
3
O-ring
From accessories set (6.1602.160).
4
Bottle attachment
From accessories set (6.1602.160).
3 Mounting aspiration filter
■
Insert filter holder (9-1) into the aspiration filter (9-2) and screw
tight.
1
2
Figure 9
Mounting aspiration filter
1
Filter holder
From accessories set (6.2744.210).
2
Aspiration filter (6.2821.090)
4 Install tubing weighting and aspiration filter
1
2
3
4
5
Figure 10
Install tubing weighting and aspiration filter
1
Eluent aspiration tubing (6.1834.080)
2
Eluent bottle attachment (6.1602.160)
3
Tubing weighting
From accessories set (6.2744.210).
4
Clamping screw
From accessories set (6.2744.210).
5
Aspiration filter (6.2821.090)
With filter holder from accessories set
(6.2744.210).
- 915 KF Ti-Touch (382 pages)
- 800 Dosino (53 pages)
- 767 Calibrated Reference (23 pages)
- 940 Professional IC Vario ONE/SeS/Prep 2 (54 pages)
- 754 Dialysis Unit (49 pages)
- 815 Robotic Soliprep for LC (76 pages)
- Vision Manual (207 pages)
- tiamo 2.1 Manual (1532 pages)
- 825 Lab Link (37 pages)
- 808 Titrando (70 pages)
- 902 Titrando (52 pages)
- 756 KF Coulometer (162 pages)
- 756 KF Coulometer (163 pages)
- 940 Professional IC Vario ONE/LPG (98 pages)
- 850 Professional IC Anion MCS Prep 3 (154 pages)
- 850 Professional IC Anion MCS Prep 3 (152 pages)
- 904 Titrando (58 pages)
- 850 Professional IC Anion MSM-HC MCS Prep 2 (150 pages)
- 930 Compact IC Flex Oven/ChS/Deg (47 pages)
- 872 Extension Module Liquid handling (64 pages)
- 814 USB Sample Processor (90 pages)
- 814 USB Sample Processor (91 pages)
- 940 Professional IC Vario (43 pages)
- Vision – Tutorial (40 pages)
- 799 GPT Titrino (242 pages)
- 889 IC Sample Center (68 pages)
- 761 Compact IC (228 pages)
- 851 Titrando (100 pages)
- 748 DH Sample Changer (32 pages)
- 940 Professional IC Vario ONE/SeS/HPG (51 pages)
- 896 Professional Detector – Amperometry (62 pages)
- 877 Titrino plus (139 pages)
- 881 Compact IC pro – Anion (129 pages)
- 940 Professional IC Vario ONE/ChS/HPG (112 pages)
- 930 Compact IC Flex Deg (41 pages)
- 840 PC Control 5.0 / Touch Control (351 pages)
- 940 Professional IC Vario ONE/Prep 1 (45 pages)
- 776 Dosimat (42 pages)
- 717 Sample Changer (36 pages)
- 815 Robotic USB Sample Processor XL (113 pages)
- 815 Robotic USB Sample Processor XL (114 pages)
- 940 Professional IC Vario ONE/SeS/PP (126 pages)
- 838 Advanced Sample Processor Installation Instructions (109 pages)
- 700 Dosino (55 pages)
- 719 S Titrino (152 pages)