Pole attachment – CommScope Trunk & Distribution Cable User Manual
Page 39
Pole Attachment
After the self-supporting cable has been placed and properly tensioned, it must be attached permanently.
Any twist (360° rotation) in the IM cable should be removed at this time.
The “C” Cable Clamp can be used for attaching the jacketed strand on QR. This is a 3-bolt clamp with
serpentine grooves to prevent slippage of the jacketed strand. Install the clamp after the web has been slit.
Integrated Messenger Installation
4.10
Pole Attachment