beautypg.com

Installation - overlashing existing cable – CommScope Trunk & Distribution Cable User Manual

Page 29

background image

Installation - Overlashing Existing Cable

Overlash Cable Placement

Overlashing cables onto existing cable plant is similar to installing cable onto new strand. However, there are

some unique aspects:

A sag and tension analysis should be performed to see if the new cable load will overwhelm the strand.

Use special overlash cable puller blocks and continuously maintain and monitor the pulling line tension. Overlash

cable pullers do not have a strand brake and will be pulled backward on the span by the tension in the cables

being pulled.

Use cable blocks designed specifically for overlash applications. Place them onto the cable bundle with a cable

block lifter and lift the cable with a cable lifter. During lashing, remove the cable blocks from the cable bundle

with a cable block lifter. DO NOT PUSH THE CABLE BLOCKS in front of the lasher as that may damage existing

cables.

Remove all straps and spacers from the existing cable bundle during lash-up. New straps and spacers may be

required - check the old ones carefully to see if they need replacing.

Aerial Installation

3.15

Overlashing