Bird Site Analyzer

74

Setting the Offset

To read unattenuated power when using a coupler or
attenuator, enter (in dB) the attenuation or coupling
factor. To convert percentages to dB, use the equation:

Attenuation(dB) = 10 x Log

10

[Attenuation(%) / 100]

Press from

Measure

Power Mode

Scroll to

Offset

Enter the

new value

Fwd

0.00 KWatts

Offset

24.00

FullScale

Measure Power Mode

Configuration Screen

Recall

Setups

16.00

dB

500.00 Watts

The offset is

displayed at

the bottom

of the main

display

Esc

Fwd

0.00 KWatts

Refl

24.00

Match

0.00 Watts

0.00 Loss(dB)

Measure Power Mode

PwrUnit

KWatts

Sensor Connected

MatchUnit

Rtn Loss

Display

Fwd

Offset 16.00 dB