AC Power Required

115V

230V

@ 50/60 Hz, 1

φ

DA10V Series

DA25V Series

DA5 Series

DA10 Series

DA15 Series

DA25 Series

DA40 Series

3.2A

2.0A

9.0A

5.0A

3.2A

2.0A

3.2A

2.0A

9.0A

5.0A

10.0A

5.0A

20.0A

10.0A

Breaker Rating

Refer to the breaker rating label on the unit.

Safety

EN 61010-1:2001

EMC

Emissions, EN 50081-1:1992
Emissions, EN 50081-1:1992
Harmonics, EN 61000-3-2:1995
Flicker, EN 61000-3-3:1995
ESD, EN 61000-4-2:1995
Radiated Immunity,

EN 61000-4-3:1995
Electrical Fast Transient/Burst,

EN 61000-4-4:1995
Surge, EN 61000-4-5:1995
Conducted, EN 61000-4-6:1995
Voltage Dips and Interrupts,

EN 61000-4-11:1995

Cooling Method

Forced air cooled

Weight, Nominal

DA5 Series

DA10, DA10V Series

DA15 Series

DA25 Series

DA25V Series

DA40 Series


100 lbs. (45.5 kg)

130 lbs. (59.0 kg)

192 lbs. (87.1 kg)

245 lbs. (111.1 kg)

150 lbs. (68.0 kg)

310 lbs. (140.6 kg)

Finish

Blue Powder Coat

*.

Typical value of the VSWR over the frequency range of the unit is 1.05:1.
This is representative of the average VSWR for the unit in question.

†.

The Duty Factor should be such that the Average Power Rating of the load
is never exceeded.

‡.

AC voltage must be within +10%, –6% of listed value.