Rockwell Automation 2099-BMxx-S Kinetix Safe Torque-off Feature Safety Reference Manual User Manual
Page 32

32
Rockwell Automation Publication GMC-RM002F-EN-P - June 2013
Appendix B Kinetix Safe Torque-off Wiring Diagrams
Kinetix Safe Torque-off/
Safety Relay Configurations
In the diagrams beginning below, the Kinetix 6000 and Kinetix 7000 drive safe
torque-off connector is shown wired to an Allen-Bradley safety relay.
Figure 18 - Single-axis Relay Configuration (Stop Category 0)
Figure 19 - Single-axis Relay Configuration (Stop Category 1)
A1
S11
S52
S12
13
23
33
41
S21
S22
S34
A2
14
24
34
42
1
2
3
4
5
6
7
8
9
N.C.
N.C.
FDBK2+
FDBK2-
FDBK1+
FDBK1-
SAFETY ENABLE2+
SAFETY ENABLE -
SAFETY ENABLE1+
24V +
24V_COM
Kinetix 6000 IAM/AM Module
or Kinetix 7000 Drive
Allen-Bradley
Monitoring Safety Relay
MSR127RP (440R-N23135)
Safe Torque-off
(STO) Connector
with
Wiring Header
External 24V COM
Safe Torque-off
Demand
External +24V DC
Reset
N.C.
N.C.
1
2
3
4
5
6
7
8
9
FDBK2+
FDBK2-
FDBK1+
FDBK1-
SAFETY ENABLE2+
SAFETY ENABLE -
SAFETY ENABLE1+
24V +
24V_COM
1
2
Hardware Enable 24V +
Hardware Enable Input
A1
S52
S11
S12
S21
S22
S33
S34
13
23
37
47
55
A2
X1
X2
X3
X4
Y39
Y40
Y2
Y1
14
24
38
48
56
Kinetix 6000 IAM/AM Module
or Kinetix 7000 Drive
Allen-Bradley Monitoring Safety Relay
MSR138.1DP (440R-M23088)
Safe Torque-off
(STO) Connector
with
Wiring Header
External 24V COM
Safe Torque-off Demand
External +24V DC
Reset
I/O (IOD) Connector