67
Ultra3000 Drive Systems
LDC-Series Performance Specifications with Ultra3000 (400V class) Drives (continued)
Linear Motor
Speed, max
m/s (ft/s)
System Continuous
Stall Current
(1)
Amps 0-pk
(1) Values represent the range between no cooling (low value) and water cooling (high value).
N (lb)
System Peak
Stall Current
Amps 0-pk
System Peak
Stall Force
N (lb)
Linear Motor
Rated Output
kW
Ultra3000
400V-class Drives
LDC-C075200-DHT
10.0 (32.8)
7.7…11.5
348…523
(78…117)
22.9
882 (198)
1.74…2.61
2098-DSD-HV100
LDC-C075200-EHT
3.8…5.7
11.5 2098-DSD-HV030
LDC-C075300-DHT
11.5…17.2
523…784
(117…176)
35.6
1368 (308)
2.61…3.92
2098-DSD-HV100
LDC-C075300-EHT
3.8…5.7
11.9 2098-DSD-HV030
LDC-C075400-DHT
15.3…23.0
697…1045
(157…235)
47.4
1824 (410)
3.48…5.22
2098-DSD-HV150
LDC-C075400-EHT
7.7…11.5
23.7 2098-DSD-HV100
LDC-C100300-DHT
10.0 (32.8)
11.1…16.7
674…1012
(152…227)
34.3
1767 (397)
3.37…5.06
2098-DSD-HV100
LDC-C100300-EHT
3.7…5.6
11.4
2098-DSD-HV030
LDC-C100400-DHT
14.8…22.2
899…1349
(202…303)
45.7
2356 (530)
4.49…6.74
2098-DSD-HV150
LDC-C100400-EHT
7.4…11.1
22.8
2098-DSD-HV100
LDC-C100600-DHT
22.2…33.3
1349…2023
(303…455)
68.5
3534 (794)
6.74…10.11
2098-DSD-HV220
LDC-C100600-EHT
11.1…16.7
34.3
2098-DSD-HV100
LDC-C150400-DHT
10.0 (32.8)
14.1…21.1
1281…1922
(288…432)
45.2
3498 (786)
6.40…9.61
2098-DSD-HV150
LDC-C150400-EHT
7.0…10.6
22.6
2098-DSD-HV100
LDC-C150600-DHT
21.1…31.7
1922…2882
(432…648)
67.8
5246 (1179)
9.61…14.41
2098-DSD-HV220
LDC-C150600-EHT
10.6…15.8
33.9
2098-DSD-HV100