beautypg.com

Rockwell Automation GV3000/SE V.6 Regulator Board 0-56921-6xx, 413338-6BU, 0-56940-6xx, 814.61.00 User Manual

Page 71

background image

10-6

GV3000/SE Drive Version 6 Regulator Board Installation Instructions

Step 5.

Install the New Regulator Board in the Drive

Step 5.1. Remove the new Regulator board from its anti-static wrapper. Make sure

the jumper settings on the new board match those on the old board. See
figure 10.4 for jumper locations.

Step 5.2. Align the two holes at the bottom of the Regulator board with the two plastic

posts. Press the Regulator board toward the drive until the posts appear
through the holes. Click into place.

Step 5.3. Connect the Regulator board to the drive using the two 3.5 mm screws.

Step 5.4. Reconnect the Regulator board to the Power Board by sliding the Regulator

board ribbon cable into the Power Module Feedback connector on the
Regulator board.

Step 6.

Drives with Option Boards Only: Install the Option Board in the Drive

Step 6.1. Align the key on the connector of the option board ribbon cable with the key

on the Regulator board connector. Press the ribbon cable connector in until
it locks into position.

Step 6.2. Attach the option board to the drive using the screws provided.

Figure 10.4 – Location of Jumpers J4 and J17 on the GV3000/SE Bookshelf Regulator Board

J17

J4

V

Out

C

Out

V

In

C

In

J17

J4

V

Out

C

Out

V

In

C

In

Terminal Strip

Power Module
Feedback Connector
(X16)

Keypad/Display
Cable Connector
(X9)

Analog Output
Default: Voltage

Analog Input
Default: Voltage

Option Board Connector
(X3)

(X1)