beautypg.com

Rockwell Automation 6181X-12TPXPDC Industrial Integrated Computers for Hazardous Locations User Manual

Page 26

background image

26

Rockwell Automation Publication 6181X-UM001B-EN-P - May 2011

Chapter 2 Installation

3. Secure the DC power wires to the terminal block screws.

Tighten the terminal to a torque of 0.687 N•m (6.1 lb•in).

4. Secure the ground wire by using a ring style connector to the functional

earth terminal screw.

Tighten to a torque of 1.47 N•m (13 lb•in).

5. Apply 18…32V DC power to the computer.

IMPORTANT

When using the functional ground screw, connect the product to earth

ground by using a 1.5 mm

2

(16 AWG) or larger external wire.

6181X-12TPXPDC

Display Computer Shown

-V +V

-V +V

6181X-NPXPDC

Non-display Computer

6181X-12TPXPDC

Display Computer