6 MobileView Machine Terminal MT750

Publication 2727-QS003E-MU-P

MobileView Junction Box Mounting and Wiring

The MobileView Junction Box (2727-MRJB1) integrates the MobileView terminal
into the control system and is mounted on a DIN rail.

S1

RJ-45 jack for connecting the MobileView data lines.

S2

9-pin DSUB female connector (for future use).

S3

RJ-45 jack to Ethernet network.

X1

12-pin male connector for connecting Junction Box Cable.

X2

12-pin male connector (shipped with female terminal block connector) for connecting the:

24V dc power supply

emergency stop switch (used only on MobileView Guard G750 Terminals)

enabling switches (used only on MobileView Guard G750 Terminals)

ATTENTION

!

The Junction Box and the MobileView terminal meet the safety class
III in accordance with EN 61131-2 and EN 50178.

When connecting the terminal, make sure all voltages connected to the
MobileView terminal are safety extra low voltages by using a safety
transformer or a similar facility.

24V D C

ON LY

TER M IN AL IN

R S422 OUT

ETH ER N ET O U T

+24V

GND

ES1+

ES1-

ES2+

ES2-

ED1 +

ED1 -

ED2 +

ED2 -

+24V

GND

ES1+

ES1-

ES2+

ES2-

ED1 +

ED1 -

ED2 +

ED2 -

S1

S2

S3

162 m

m

(6

.4

in

)

X1

(with Female

Terminal Block

Connector K3)

X2

(with Female

Terminal Block

Connector K4)

Pin 1, 24V dc

Pin 1, 24V dc

DIN Rail Latch

Grounding
Screw

Strain Relief

60 mm (2.36 in)

150 mm (5.91 in)

108 mm (4.25 in

Grounding Screw