Using RSLinx Gateways

8-5

Publication 9303-5.13 – March 1998

Setting the
Communication
Information

To provide DriveTools32 with information that it needs to establish a connection
between your PC and your drive, you need to:

1.

Start DriveManager32.

2.

From the Options menu, select Communication Setup. The
Communication Setup dialog box appears.

3.

In the Communications section, select Remote devices (Gateway).

4.

In the Communications Type section, select the appropriate
communications type.

5.

In the Enter mapping TCP Port # to use field, enter the KT Port number.

Important: The Port number must match the RSLinx KT:0 Port number used for
the TCP device in the Configure Client Applications dialog box.

6.

If applicable, select 1336T Two Word Header (used ONLY for 1336T
version 0.10)
.

7.

Click OK. A window displaying information on RIO Pass Thru
communications may appear.

8.

Click OK.